This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
Specimen Reject Example (id = "unsat")
<?xml version="1.0" encoding="UTF-8"?> <Observation xmlns="http://hl7.org/fhir"> <id value="unsat"/> <!-- urn:oid:2.16.840.1.113883.4.642.1.7 --> <!-- 2.16.840.1.113883.4.642.1.118 --> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Observation</b> <a name="unsat"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation "unsat" </p> </div> <p> <b> identifier</b> : <span title=" urn:oid:2.16.840.1.113883.4.642.1.7 &#10; 2.16.840.1.113883.4.642.1.118 ">id: 6323 (OFFICIAL)</span> </p> <p> <b> status</b> : cancelled</p> <p> <b> code</b> : Glucose [Moles/volume] in Blood <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a> #15074-8)</span> </p> <p> <b> subject</b> : <a href="patient-example-f001-pieter.html">Patient/f001: P. van de Heuvel</a> "Pieter VAN DE HEUVEL"</p> <p> <b> effective</b> : 2013-04-02T09:30:10+01:00</p> <p> <b> issued</b> : 04/04/2013 1:30:10 AM</p> <p> <b> performer</b> : <a href="practitioner-example-f005-al.html">Practitioner/f005: A. Langeveld</a> "Langeveld ANNE"</p> <p> <b> dataAbsentReason</b> : Specimen unsatisfactory for evaluation <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #125154007)</span> </p> <p> <b> note</b> : Tube broken in transit and sample leaked</p> <h3> ReferenceRanges</h3> <table class="grid"><tr> <td> -</td> <td> <b> Low</b> </td> <td> <b> High</b> </td> </tr> <tr> <td> *</td> <td> 3.1 mmol/l<span style="background: LightGoldenRodYellow"> (Details: UCUM code mmol/L = 'mmol/L')</span> </td> <td> 6.2 mmol/l<span style="background: LightGoldenRodYellow"> (Details: UCUM code mmol/L = 'mmol/L')</span> </td> </tr> </table> </div> </text> <identifier> <use value="official"/> <system value="http://www.bmc.nl/zorgportal/identifiers/observations"/> <value value="6323"/> </identifier> <status value="cancelled"/> <code> <coding> <system value="http://loinc.org"/> <code value="15074-8"/> <display value="Glucose [Moles/volume] in Blood"/> </coding> </code> <subject> <reference value="Patient/f001"/> <display value="P. van de Heuvel"/> </subject> <effectiveDateTime value="2013-04-02T09:30:10+01:00"/> <issued value="2013-04-03T15:30:10+01:00"/> <performer> <reference value="Practitioner/f005"/> <display value="A. Langeveld"/> </performer> <dataAbsentReason> <coding> <system value="http://snomed.info/sct"/> <code value="125154007"/> <display value="Specimen unsatisfactory for evaluation"/> </coding> </dataAbsentReason> <note> <text value="Tube broken in transit and sample leaked"/> </note> <referenceRange> <low> <value value="3.1"/> <unit value="mmol/l"/> <system value="http://unitsofmeasure.org"/> <code value="mmol/L"/> </low> <high> <value value="6.2"/> <unit value="mmol/l"/> <system value="http://unitsofmeasure.org"/> <code value="mmol/L"/> </high> </referenceRange> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.