This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
Spirometry Example referencing DeviceComponent (id = "656")
<?xml version="1.0" encoding="UTF-8"?> <Observation xmlns="http://hl7.org/fhir"> <id value="656"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Observation</b> <a name="656"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation "656" </p> </div> <p> <b> identifier</b> : id: patientId-urn:oid:1.2.4~0000000000000000~152584~20170503155426~820</p> <p> <b> status</b> : final</p> <p> <b> code</b> : MDC_FLOW_AWAY_EXP_FORCED_PEAK <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #152584)</span> </p> <p> <b> subject</b> : <a href="todo.html">Patient/PatientId-patientId</a> </p> <p> <b> effective</b> : 2017-05-03T15:54:26-04:00</p> <p> <b> performer</b> : <a href="todo.html">Patient/PatientId-patientId</a> </p> <p> <b> value</b> : 820 cL/s<span style="background: LightGoldenRodYellow"> (Details: urn:iso:std:iso:11073:10101 code 265201 = '265201')</span> </p> </div> </text> <identifier> <value value="patientId-urn:oid:1.2.4~0000000000000000~152584~20170503155426~820"/> </identifier> <status value="final"/> <code> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="152584"/> <display value="MDC_FLOW_AWAY_EXP_FORCED_PEAK"/> </coding> </code> <subject> <reference value="Patient/PatientId-patientId"/> </subject> <effectiveDateTime value="2017-05-03T15:54:26-04:00"/> <performer> <reference value="Patient/PatientId-patientId"/> </performer> <valueQuantity> <value value="820"/> <unit value="cL/s"/> <system value="urn:iso:std:iso:11073:10101"/> <code value="265201"/> </valueQuantity> <!-- - Removed the .related type qualified-by - if needed would be an extension <related> <type value="qualified-by"/> <target> <identifier> <value value="3.14159.20170619185932"/> </identifier> </target> </related> --> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.