This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile Observation.
Generated Narrative: Observation
Resource Observation "satO2"
Profile: Vital Signs Profile
identifier: id: o1223435-10
partOf: Procedure/ob
status: final
category: Vital Signs (Observation Category Codes#vital-signs)
code: Oxygen saturation in Arterial blood (LOINC#2708-6; LOINC#59408-5 "Oxygen saturation in Arterial blood by Pulse oximetry"; ISO 11073-10101 Health informatics - Point-of-care#150456 "MDC_PULS_OXIM_SAT_O2")
subject: Patient/example "Peter CHALMERS"
effective: 2014-12-05T09:30:10+01:00
value: 95 % (Details: UCUM code % = '%')
interpretation: Normal (applies to non-numeric results) (ObservationInterpretation#N "Normal")
device: DeviceMetric/example
- | Low | High |
* | 90 % (Details: UCUM code % = '%') | 99 % (Details: UCUM code % = '%') |
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.