This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner |
Raw XML (canonical form + also see XML Format Specification)
Request for Intravenous Admixture Dopamine - with rateQuantity (id = "medrx0337")
<?xml version="1.0" encoding="UTF-8"?> <MedicationRequest xmlns="http://hl7.org/fhir"> <id value="medrx0337"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: MedicationRequest</b> <a name="medrx0337"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource MedicationRequest "medrx0337" </p> </div> <p> <b> identifier</b> : id: 12345689 (OFFICIAL)</p> <p> <b> status</b> : completed</p> <p> <b> intent</b> : order</p> <h3> Medications</h3> <table class="grid"><tr> <td> -</td> <td> <b> Reference</b> </td> </tr> <tr> <td> *</td> <td> <span title=" Linked to a RESOURCE Medication "><a name="med0337"> </a> </span> <blockquote> <p/> <p> <a name="med0337"> </a> </p> <p> <b> doseForm</b> : Injection Solution (qualifier value) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #385219001)</span> </p> <blockquote> <p> <b> ingredient</b> </p> <h3> Items</h3> <table class="grid"><tr> <td> -</td> <td> <b> Concept</b> </td> </tr> <tr> <td> *</td> <td> Dopamine <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-rxNorm.html">RxNorm</a> #1114879)</span> </td> </tr> </table> <p> <b> strength</b> : 400 mg<span style="background: LightGoldenRodYellow"> (Details: UCUM code mg = 'mg')</span> /500 mL<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span> </p> </blockquote> <blockquote> <p> <b> ingredient</b> </p> <h3> Items</h3> <table class="grid"><tr> <td> -</td> <td> <b> Concept</b> </td> </tr> <tr> <td> *</td> <td> Dextrose 5% injection USP <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-ndc.html">National drug codes</a> #0264-7510-10)</span> </td> </tr> </table> <p> <b> strength</b> : 5 g<span style="background: LightGoldenRodYellow"> (Details: UCUM code g = 'g')</span> /100 mL<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span> </p> </blockquote> </blockquote> </td> </tr> </table> <p> <b> subject</b> : <a href="patient-example-a.html">Patient/pat1: Donald Duck</a> "Donald DUCK"</p> <p> <b> authoredOn</b> : 2015-01-15</p> <p> <b> requester</b> : <a href="practitioner-example-f007-sh.html">Practitioner/f007: Patrick Pump</a> "Simone HEPS"</p> <blockquote> <p> <b> dose</b> </p> <blockquote> <p> <b> dosageInstruction</b> </p> <p> <b> sequence</b> : 1</p> <p> <b> text</b> : Dopamine 4mcg/kg/min</p> <p> <b> timing</b> : Duration 33.33?ngen-7?, Do Once</p> <p> <b> route</b> : Intravenous route (qualifier value) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #47625008)</span> </p> </blockquote> </blockquote> </div> </text> <contained> <Medication> <id value="med0337"/> <doseForm> <coding> <system value="http://snomed.info/sct"/> <code value="385219001"/> <display value="Injection Solution (qualifier value)"/> </coding> <text value="Injection Solution (qualifier value)"/> </doseForm> <ingredient> <item> <concept> <coding> <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> <code value="1114879"/> <display value="Dopamine"/> </coding> </concept> </item> <strengthRatio> <numerator> <value value="400"/> <system value="http://unitsofmeasure.org"/> <code value="mg"/> </numerator> <denominator> <value value="500"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </strengthRatio> </ingredient> <ingredient> <item> <concept> <coding> <system value="http://hl7.org/fhir/sid/ndc"/> <code value="0264-7510-10"/> <display value="Dextrose 5% injection USP"/> </coding> </concept> </item> <strengthRatio> <numerator> <value value="5"/> <system value="http://unitsofmeasure.org"/> <code value="g"/> </numerator> <denominator> <value value="100"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </strengthRatio> </ingredient> </Medication> </contained> <identifier> <use value="official"/> <system value="http://www.bmc.nl/portal/prescriptions"/> <value value="12345689"/> </identifier> <status value="completed"/> <intent value="order"/> <medication> <!-- Linked to a RESOURCE Medication --> <reference> <reference value="#med0337"/> <display value="Dopamine 400mg in 500mL D5W"/> </reference> </medication> <subject> <!-- Linked to the resource patient who needs the medication --> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </subject> <authoredOn value="2015-01-15"/> <requester> <reference value="Practitioner/f007"/> <display value="Patrick Pump"/> </requester> <dose> <dosageInstruction> <sequence value="1"/> <text value="Dopamine 4mcg/kg/min"/> <timing> <repeat> <duration value="33.33"/> <durationUnit value="h"/> </repeat> </timing> <route> <coding> <system value="http://snomed.info/sct"/> <code value="47625008"/> <display value="Intravenous route (qualifier value)"/> </coding> </route> <doseAndRate> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/dose-rate-type"/> <code value="ordered"/> <display value="Ordered"/> </coding> </type> <rateQuantity> <value value="200"/> <unit value="ug/min"/> <system value="http://unitsofmeasure.org"/> </rateQuantity> </doseAndRate> </dosageInstruction> </dose> </MedicationRequest>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.