This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Lorazepam with a Device
{ "resourceType": "MedicationAdministration", "id": "medadmin0307", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: MedicationAdministration</b><a name=\"medadmin0307\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource MedicationAdministration "medadmin0307" </p></div><p><b>status</b>: completed</p><h3>Medications</h3><table class=\"grid\"><tr><td>-</td><td><b>Reference</b></td></tr><tr><td>*</td><td><a name=\"med0313\"> </a><blockquote><p/><p><a name=\"med0313\"> </a></p><p><b>code</b>: Lorazepam 2mg/ml injection solution 1ml vial (product) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#400621001)</span></p><p><b>doseForm</b>: Injection solution (qualifier value) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#385219001)</span></p><blockquote><p><b>ingredient</b></p><h3>Items</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td></tr><tr><td>*</td><td>Lorazepam (substance) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#387106007)</span></td></tr></table><p><b>strength</b>: 2 mg<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mg = 'mg')</span>/1 mL<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mL = 'mL')</span></p></blockquote></blockquote></td></tr></table><p><b>subject</b>: <a href=\"patient-example-a.html\">Patient/pat1: Donald Duck</a> "Donald DUCK"</p><p><b>encounter</b>: <a href=\"encounter-example-f001-heart.html\">Encounter/f001: encounter who leads to this prescription</a></p><p><b>occurence</b>: 2015-01-15T04:30:00+01:00 --> 2015-01-15T14:30:00+01:00</p><h3>Performers</h3><table class=\"grid\"><tr><td>-</td><td><b>Function</b></td><td><b>Actor</b></td></tr><tr><td>*</td><td>Performer <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-med-admin-perform-function.html\">MedicationAdministration Performer Function Codes</a>#performer)</span></td><td><a href=\"practitioner-example-f007-sh.html\">Practitioner/f007: Patrick Pump</a> "Simone HEPS"</td></tr></table><p><b>request</b>: <a href=\"medicationrequest0315.html\">MedicationRequest/medrx0315</a></p><p><b>device</b>: <a href=\"device-example-f001-feedingtube.html\">Device/f001</a></p><h3>Dosages</h3><table class=\"grid\"><tr><td>-</td><td><b>Text</b></td><td><b>Route</b></td><td><b>Method</b></td><td><b>Dose</b></td><td><b>Rate[x]</b></td></tr><tr><td>*</td><td>0.05 - 0.1mg/kg IV over 2-5 minutes every 15 minutes as needed</td><td>Intravenous <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#255560000)</span></td><td>Push - dosing instruction imperative (qualifier value) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#420620005)</span></td><td>7 mg<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mg = 'mg')</span></td><td>4 min<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code min = 'min')</span></td></tr></table></div>" }, "contained": [ { "resourceType": "Medication", "id": "med0313", "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "400621001", "display": "Lorazepam 2mg/ml injection solution 1ml vial (product)" } ] }, "doseForm": { "coding": [ { "system": "http://snomed.info/sct", "code": "385219001", "display": "Injection solution (qualifier value)" } ] }, "ingredient": [ { "item": { "concept": { "coding": [ { "system": "http://snomed.info/sct", "code": "387106007", "display": "Lorazepam (substance)" } ] } }, "strengthRatio": { "numerator": { "value": 2, "system": "http://unitsofmeasure.org", "code": "mg" }, "denominator": { "value": 1, "system": "http://unitsofmeasure.org", "code": "mL" } } } ] } ], "status": "completed", "medication": { "reference": { "reference": "#med0313" } }, "subject": { "reference": "Patient/pat1", "display": "Donald Duck" }, "encounter": { "reference": "Encounter/f001", "display": "encounter who leads to this prescription" }, "occurencePeriod": { "start": "2015-01-15T04:30:00+01:00", "end": "2015-01-15T14:30:00+01:00" }, "performer": [ { "function": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/med-admin-perform-function", "code": "performer", "display": "Performer" } ] }, "actor": { "reference": "Practitioner/f007", "display": "Patrick Pump" } } ], "request": { "reference": "MedicationRequest/medrx0315" }, "device": [ { "reference": "Device/f001" } ], "dosage": { "text": "0.05 - 0.1mg/kg IV over 2-5 minutes every 15 minutes as needed", "route": { "coding": [ { "system": "http://snomed.info/sct", "code": "255560000", "display": "Intravenous" } ] }, "method": { "coding": [ { "system": "http://snomed.info/sct", "code": "420620005", "display": "Push - dosing instruction imperative (qualifier value)" } ] }, "dose": { "value": 7, "unit": "mg", "system": "http://unitsofmeasure.org", "code": "mg" }, "rateQuantity": { "value": 4, "unit": "min", "system": "http://unitsofmeasure.org", "code": "min" } } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.