This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Clinical Decision Support Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
Example of guidanceresponse
{ "resourceType": "GuidanceResponse", "id": "example", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: GuidanceResponse</b><a name=\"example\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource GuidanceResponse "example" </p></div><p><b>requestIdentifier</b>: id: guidanceRequest1</p><p><b>identifier</b>: id: guidanceResponse1</p><p><b>module</b>: <a href=\"http://someguidelineprovider.org/radiology-appropriateness-guidelines.html\">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p><p><b>status</b>: success</p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</p><p><b>encounter</b>: <a href=\"encounter-example.html\">Encounter/example</a></p><p><b>occurrenceDateTime</b>: 2017-03-10T16:02:00Z</p><p><b>performer</b>: <a href=\"todo.html\">Device/software</a></p><h3>Reasons</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td></tr><tr><td>*</td><td>Guideline Appropriate Ordering Assessment <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></td></tr></table><p><b>outputParameters</b>: <a name=\"outputParameters1\"> </a></p><blockquote><p/><p><a name=\"outputParameters1\"> </a></p><blockquote><p><b>parameter</b></p><p><b>name</b>: score</p><p><b>value</b>: 7</p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: item-assessed</p><p><b>value</b>: CT, head, wo iv contrast <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-CPT.html\">Current Procedural Terminology (CPT®)</a>#70450)</span></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: device</p><p><b>value</b>: <a href=\"todo.html\">Device/software</a></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: guideline-followed</p><p><b>value</b>: <a href=\"http://someguidelineprovider.org/radiology-appropriateness-guidelines.html\">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p></blockquote></blockquote></div>" }, "contained": [ { "resourceType": "Parameters", "id": "outputParameters1", "parameter": [ { "name": "score", "valueDecimal": 7 }, { "name": "item-assessed", "valueCodeableConcept": { "coding": [ { "system": "http://www.ama-assn.org/go/cpt", "code": "70450", "display": "CT, head, wo iv contrast" } ] } }, { "name": "device", "valueReference": { "reference": "Device/software" } }, { "name": "guideline-followed", "valueUri": "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html" } ] } ], "requestIdentifier": { "system": "http://example.org", "value": "guidanceRequest1" }, "identifier": [ { "system": "http://example.org", "value": "guidanceResponse1" } ], "moduleUri": "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html", "status": "success", "subject": { "reference": "Patient/example" }, "encounter": { "reference": "Encounter/example" }, "occurrenceDateTime": "2017-03-10T16:02:00Z", "performer": { "reference": "Device/software" }, "reason": [ { "concept": { "text": "Guideline Appropriate Ordering Assessment" } } ], "outputParameters": { "reference": "#outputParameters1" } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.