This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Patient |
Raw JSON (canonical form + also see JSON Format Specification)
example-udi3
{ "resourceType": "Device", "id": "example-udi3", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"example-udi3\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "example-udi3" </p></div><p><b>identifier</b>: Serial Number: XYZ456789012345678</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>007444534255003288</td><td><a href=\"http://hl7.org/fhir/NamingSystem/hibcc\">http://hl7.org/fhir/NamingSystem/hibcc</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>+H123PARTNO1234567890120/$$420020216LOT123456789012345/SXYZ456789012345678/16D20130202C</td><td>manual</td></tr></table><p><b>status</b>: inactive</p><p><b>manufacturer</b>: GlobalMed, Inc</p><p><b>manufactureDate</b>: 2013-02-02</p><p><b>expirationDate</b>: 2020-02-02</p><p><b>lotNumber</b>: LOT123456789012345</p><h3>DeviceNames</h3><table class=\"grid\"><tr><td>-</td><td><b>Name</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>Ultra Implantable</td><td>user-friendly-name</td></tr></table><h3>Associations</h3><table class=\"grid\"><tr><td>-</td><td><b>Status</b></td><td><b>HumanSubject</b></td></tr><tr><td>*</td><td>attached <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (device-association-status#attached)</span></td><td><a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</td></tr></table></div>" }, "identifier": [ { "type": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/v2-0203", "code": "SNO" } ] }, "value": "XYZ456789012345678" } ], "udiCarrier": [ { "deviceIdentifier": "007444534255003288", "issuer": "http://hl7.org/fhir/NamingSystem/hibcc", "jurisdiction": "http://hl7.org/fhir/NamingSystem/fda-udi", "carrierHRF": "+H123PARTNO1234567890120/$$420020216LOT123456789012345/SXYZ456789012345678/16D20130202C", "entryType": "manual" } ], "status": "inactive", "manufacturer": "GlobalMed, Inc", "manufactureDate": "2013-02-02", "expirationDate": "2020-02-02", "lotNumber": "LOT123456789012345", "deviceName": [ { "name": "Ultra Implantable", "type": "user-friendly-name" } ], "association": [ { "status": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/device-association-status", "code": "attached" } ] }, "humanSubject": { "reference": "Patient/example" } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.