This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Patient |
Raw XML (canonical form + also see XML Format Specification)
example-udi2 (id = "example-udi2")
<?xml version="1.0" encoding="UTF-8"?> <Device xmlns="http://hl7.org/fhir"> <id value="example-udi2"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="example-udi2"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device "example-udi2" </p> </div> <p> <b> identifier</b> : A99971312345600</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> </tr> <tr> <td> *</td> <td> A9999XYZ100T0474</td> <td> <a href="http://hl7.org/fhir/NamingSystem/iccbba-other">http://hl7.org/fhir/NamingSystem/iccbba-other</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> </tr> </table> <p> <b> status</b> : inactive</p> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> manufactureDate</b> : 2013-02-01</p> <p> <b> expirationDate</b> : <span title=" 013032 = this is the manufacturing date expressed in YYYDDD (three digit year, three digit day number) ">2014-02-01</span> </p> <h3> Associations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Status</b> </td> <td> <b> HumanSubject</b> </td> </tr> <tr> <td> *</td> <td> attached <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (device-associationstatus#attached)</span> </td> <td> <a href="patient-example.html">Patient/example</a> "Peter CHALMERS"</td> </tr> </table> </div> </text> <identifier> <type> <coding> <system value="http://hl7.org/fhir/NamingSystem/iccbba-din"/> </coding> </type> <value value="A99971312345600"/> </identifier> <udiCarrier> <deviceIdentifier value="A9999XYZ100T0474"/> <issuer value="http://hl7.org/fhir/NamingSystem/iccbba-other"/> <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> </udiCarrier> <status value="inactive"/> <manufacturer value="Acme Devices, Inc"/> <manufactureDate value="2013-02-01"/> <!-- 013032 = this is the manufacturing date expressed in YYYDDD (three digit year, three digit day number) --> <expirationDate value="2014-02-01"/> <!-- 014032 = this is the expiration date expressed in YYYDDD (three digit year, three digit day number) --> <association> <status> <coding> <system value="http://terminology.hl7.org/CodeSystem/device-associationstatus"/> <code value="attached"/> </coding> </status> <humanSubject> <reference value="Patient/example"/> </humanSubject> </association> </Device>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.