This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Patient |
Raw JSON (canonical form + also see JSON Format Specification)
example-udi1
{ "resourceType": "Device", "id": "example-udi1", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"example-udi1\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "example-udi1" </p></div><p><b>identifier</b>: 1234-5678-90AB-CDEF, Serial Number: 10987654d321</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierAIDC</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>00844588003288</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1\">http://hl7.org/fhir/NamingSystem/gs1</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH</td><td>{01}00844588003288{17}141120{10}7654321D{21}10987654d321</td><td>barcode</td></tr></table><p><b>status</b>: active</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>expirationDate</b>: 2014-11-20</p><p><b>lotNumber</b>: 7654321D</p><h3>DeviceNames</h3><table class=\"grid\"><tr><td>-</td><td><b>Name</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>PM/Octane 2014</td><td>user-friendly-name</td></tr></table><p><b>type</b>: Coated femoral stem prosthesis, modular <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#468063009)</span></p><h3>Associations</h3><table class=\"grid\"><tr><td>-</td><td><b>Status</b></td><td><b>HumanSubject</b></td></tr><tr><td>*</td><td>attached <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (device-association-status#attached)</span></td><td><a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</td></tr></table><p><b>safety</b>: MR Unsafe <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (unknown#mr-unsafe)</span></p></div>" }, "identifier": [ { "type": { "coding": [ { "system": "http://acme.com/devices/pacemakers/octane/serial" } ] }, "value": "1234-5678-90AB-CDEF" }, { "type": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/v2-0203", "code": "SNO" } ] }, "value": "10987654d321" } ], "udiCarrier": [ { "deviceIdentifier": "00844588003288", "issuer": "http://hl7.org/fhir/NamingSystem/gs1", "jurisdiction": "http://hl7.org/fhir/NamingSystem/fda-udi", "carrierAIDC": "XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH", "carrierHRF": "{01}00844588003288{17}141120{10}7654321D{21}10987654d321", "entryType": "barcode" } ], "status": "active", "manufacturer": "Acme Devices, Inc", "expirationDate": "2014-11-20", "lotNumber": "7654321D", "deviceName": [ { "name": "PM/Octane 2014", "type": "user-friendly-name" } ], "type": [ { "coding": [ { "system": "http://snomed.info/sct", "code": "468063009", "display": "Coated femoral stem prosthesis, modular" } ], "text": "Coated femoral stem prosthesis, modular" } ], "association": [ { "status": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/device-association-status", "code": "attached" } ] }, "humanSubject": { "reference": "Patient/example" } } ], "safety": [ { "coding": [ { "system": "urn:oid:2.16.840.1.113883.3.26.1.1", "code": "mr-unsafe", "display": "MR Unsafe" } ], "text": "MR Unsafe" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.