Release 5 Ballot

This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Example Device/NoninBlePulseOx (Narrative)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile Device.


Generated Narrative: Device

Resource Device "NoninBlePulseOx"

identifier: System Identifier: 74-E8-FF-FE-FF-05-1C-00, Bluetooth Address: 00-1C-05-FF-E8-74

UdiCarriers

-DeviceIdentifierIssuerJurisdictionCarrierHRFEntryType
*120359741556http://hl7.org/fhir/NamingSystem/gs1-dihttp://hl7.org/fhir/NamingSystem/fda-udi(01)120359741556(21)501900083unknown

manufacturer: Nonin_Medical_Inc.

serialNumber: 501900083

DeviceNames

-NameType
*Nonin3230_501900083user-friendly-name

modelNumber: Model 3230

type: MDC_MOC_VMS_MDS_SIMP: Personal Health Device (ISO 11073-10101 Health informatics - Point-of-care#65573 "MDC_MOC_VMS_MDS_SIMP")

version

type: MDC_ID_PROD_SPEC_FW: Firmware revision (ISO 11073-10101 Health informatics - Point-of-care#531976)

value: r2.1

version

type: MDC_ID_PROD_SPEC_SW: Software revision (ISO 11073-10101 Health informatics - Point-of-care#531975)

value: r1.5 9.7

version

type: MDC_ID_PROD_SPEC_HW: Hardware revision (ISO 11073-10101 Health informatics - Point-of-care#531974)

value: r1.0

version

type: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version (ISO 11073-10101 Health informatics - Point-of-care#532352)

value: 6.0

Specializations

-SystemTypeVersion
*MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter (ISO 11073-10101 Health informatics - Point-of-care#528388)1

property

type: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list (ISO 11073-10101 Health informatics - Point-of-care#532353)

value: 4 (ContinuaPAN#4)

property

type: regulation-status (ASN1ToHL7#532354.0)

value: Device is Regulated (v2-0136#N)

property

type: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol (ISO 11073-10101 Health informatics - Point-of-care#68220)

value: MDC_TIME_SYNC_NONE: No time synchronization (ISO 11073-10101 Health informatics - Point-of-care#532224)

property

type: mds-time-capab-real-time-clock (ASN1ToHL7#68219.0)

value: real time clock supported (v2-0136#Y)

property

type: mds-time-capab-set-clock (ASN1ToHL7#68219.1)

value: setting the time supported (v2-0136#Y)


 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.