Release 5 Ballot

This page is part of the FHIR Specification (v5.0.0-ballot: FHIR R5 Ballot Preview). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Example GenomicStudy/NGS-device (Turtle)

Clinical Genomics Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

Raw Turtle (+ also see Turtle/RDF Format Specification)

Device - NGS Device

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

[a fhir:Device;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "NGS-device"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource &quot;NGS-device&quot; </p></div><p><b>identifier</b>: id: 11111</p><p><b>status</b>: active</p><p><b>manufacturer</b>: Illumina</p><h3>DeviceNames</h3><table class=\"grid\"><tr><td>-</td><td><b>Name</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>NextSeq 550 Instrument</td><td>user-friendly-name</td></tr></table><p><b>type</b>: Device (physical object) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#49062001)</span></p></div>"
  ];
  fhir:Device.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "http://www.somesystemabc.net/identifiers/devices" ];
     fhir:Identifier.value [ fhir:value "11111" ]
  ];
  fhir:Device.status [ fhir:value "active"];
  fhir:Device.manufacturer [ fhir:value "Illumina"];
  fhir:Device.deviceName [
     fhir:index 0;
     fhir:Device.deviceName.name [ fhir:value "NextSeq 550 Instrument" ];
     fhir:Device.deviceName.type [ fhir:value "user-friendly-name" ]
  ];
  fhir:Device.type [
     fhir:index 0;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:49062001;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "49062001" ];
       fhir:Coding.display [ fhir:value "Device (physical object)" ]
     ]
  ]] .

# - ontology header ------------------------------------------------------------

[a owl:Ontology;
  owl:imports fhir:fhir.ttl] .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.