Release 4B Snapshot #1

This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Valueset-observation-vitalsignresult.json

Vocabulary Work GroupMaturity Level: N/AStandards Status: Informative

Raw JSON (canonical form + also see JSON Format Specification)

Definition for Value SetVital Signs

{
  "resourceType" : "ValueSet",
  "id" : "observation-vitalsignresult",
  "meta" : {
    "lastUpdated" : "2021-12-20T14:08:35.086+11:00",
    "profile" : ["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]
  },
  "text" : {
    "status" : "generated",
    "div" : "<div>!-- Snipped for Brevity --></div>"
  },
  "extension" : [{
    "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
    "valueCode" : "oo"
  }],
  "url" : "http://hl7.org/fhir/ValueSet/observation-vitalsignresult",
  "identifier" : [{
    "system" : "urn:ietf:rfc:3986",
    "value" : "urn:oid:2.16.840.1.113883.3.88.12.80.62"
  }],
  "version" : "4.3.0-snapshot1",
  "name" : "VitalSigns",
  "title" : "Vital Signs",
  "status" : "active",
  "publisher" : "FHIR project team",
  "contact" : [{
    "telecom" : [{
      "system" : "url",
      "value" : "http://hl7.org/fhir"
    }]
  }],
  "description" : "This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).",
  "copyright" : "This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use",
  "compose" : {
    "include" : [{
      "system" : "http://loinc.org",
      "concept" : [{
        "code" : "85353-1"
      },
      {
        "code" : "9279-1"
      },
      {
        "code" : "8867-4"
      },
      {
        "code" : "2708-6"
      },
      {
        "code" : "8310-5"
      },
      {
        "code" : "8302-2"
      },
      {
        "code" : "9843-4"
      },
      {
        "code" : "29463-7"
      },
      {
        "code" : "39156-5"
      },
      {
        "code" : "85354-9"
      },
      {
        "code" : "8480-6"
      },
      {
        "code" : "8462-4"
      },
      {
        "code" : "8478-0"
      }]
    }]
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.