Release 4B Snapshot #1

This page is part of the FHIR Specification v4.3.0-snapshot1: R4B Snapshot to support the Jan 2022 Connectathon. About the R4B version of FHIR. The current officially released version is 4.3.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

4.4.1.247 Value Set http://hl7.org/fhir/ValueSet/diagnostic-report-status

Orders and Observations Work Group Maturity Level: 3Trial Use Use Context: Any

This is a value set defined by the FHIR project.

Summary

Defining URL:http://hl7.org/fhir/ValueSet/diagnostic-report-status
Version:4.3.0-snapshot1
Name:DiagnosticReportStatus
Title:DiagnosticReportStatus
Definition:

The status of the diagnostic report.

Committee:Orders and Observations Work Group
OID:2.16.840.1.113883.4.642.3.235 (for OID based terminology systems)
Source ResourceXML / JSON

This value set is used in the following places:


 

This expansion generated 20 Dec 2021


This value set contains 10 concepts

Expansion based on DiagnosticReportStatus v4.3.0-snapshot1 (CodeSystem)

All codes in this table are from the system http://hl7.org/fhir/diagnostic-report-status

LvlCodeDisplayDefinition
0registeredRegisteredThe existence of the report is registered, but there is nothing yet available.
0partialPartialThis is a partial (e.g. initial, interim or preliminary) report: data in the report may be incomplete or unverified.
1  preliminaryPreliminaryVerified early results are available, but not all results are final.
0finalFinalThe report is complete and verified by an authorized person.
0amendedAmendedSubsequent to being final, the report has been modified. This includes any change in the results, diagnosis, narrative text, or other content of a report that has been issued.
1  correctedCorrectedSubsequent to being final, the report has been modified to correct an error in the report or referenced results.
1  appendedAppendedSubsequent to being final, the report has been modified by adding new content. The existing content is unchanged.
0cancelledCancelledThe report is unavailable because the measurement was not started or not completed (also sometimes called "aborted").
0entered-in-errorEntered in ErrorThe report has been withdrawn following a previous final release. This electronic record should never have existed, though it is possible that real-world decisions were based on it. (If real-world activity has occurred, the status should be "cancelled" rather than "entered-in-error".).
0unknownUnknownThe authoring/source system does not know which of the status values currently applies for this observation. Note: This concept is not to be used for "other" - one of the listed statuses is presumed to apply, but the authoring/source system does not know which.

 

See the full registry of value sets defined as part of FHIR.


Explanation of the columns that may appear on this page:

LvlA few code lists that FHIR defines are hierarchical - each code is assigned a level. For value sets, levels are mostly used to organize codes for user convenience, but may follow code system hierarchy - see Code System for further information
SourceThe source of the definition of the code (when the value set draws in codes defined elsewhere)
CodeThe code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
DisplayThe display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
DefinitionAn explanation of the meaning of the concept
CommentsAdditional notes about how to use the code