This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Vocabulary Work Group | Maturity Level: N/A | Standards Status: Informative |
Raw XML (canonical form + also see XML Format Specification)
Definition for Value SetAllergyIntolerance Substance/Product, Condition and Negation Codes
<?xml version="1.0" encoding="UTF-8"?> <ValueSet xmlns="http://hl7.org/fhir"> <id value="allergyintolerance-code"/> <meta> <lastUpdated value="2021-12-20T14:08:35.086+11:00"/> <profile value="http://hl7.org/fhir/StructureDefinition/shareablevalueset"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p> This value set includes codes based on the following rules:</p> <ul> <li> Import all the codes that are contained in <a href="valueset-substance-code.html">http://hl7.org/fhir/ValueSet/substance-code</a> </li> <li> Include codes from <a href="http://www.snomed.org/"> <code> http://snomed.info/sct</code> </a> where concept is-a 418038007 (Propensity to adverse reactions to substance) </li> <li> Include codes from <a href="http://www.snomed.org/"> <code> http://snomed.info/sct</code> </a> where concept is-a 267425008 (Lactose intolerance) </li> <li> Include codes from <a href="http://www.snomed.org/"> <code> http://snomed.info/sct</code> </a> where concept is-a 29736007 (Syndrome of carbohydrate intolerance) </li> <li> Include codes from <a href="http://www.snomed.org/"> <code> http://snomed.info/sct</code> </a> where concept is-a 340519003 (Lysine intolerance) </li> <li> Include codes from <a href="http://www.snomed.org/"> <code> http://snomed.info/sct</code> </a> where concept is-a 190753003 (Sucrose intolerance) </li> <li> Include codes from <a href="http://www.snomed.org/"> <code> http://snomed.info/sct</code> </a> where concept is-a 413427002 (Acquired fructose intolerance) </li> <li> Include codes from <a href="http://www.snomed.org/"> <code> http://snomed.info/sct</code> </a> where concept is-a 716186003 (No known allergy) </li> </ul> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"> <valueCode value="pc"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status"> <valueCode value="draft"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm"> <valueInteger value="1"/> </extension> <url value="http://hl7.org/fhir/ValueSet/allergyintolerance-code"/> <identifier> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.840.1.113883.4.642.3.137"/> </identifier> <version value="4.3.0-snapshot1"/> <name value="AllergyIntoleranceSubstance/Product,ConditionAndNegationCodes"/> <title value="AllergyIntolerance Substance/Product, Condition and Negation Codes"/> <status value="draft"/> <experimental value="true"/> <publisher value="FHIR Project team"/> <contact> <telecom> <system value="url"/> <value value="http://hl7.org/fhir"/> </telecom> </contact> <description value="This value set includes concept codes for specific substances/pharmaceutical products, allergy or intolerance conditions, and negation/exclusion codes to specify the absence of specific types of allergies or intolerances."/> <copyright value="This resource includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these specifications must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomed-ct or info@snomed.org"/> <compose> <include> <valueSet value="http://hl7.org/fhir/ValueSet/substance-code"/> </include> <include> <system value="http://snomed.info/sct"/> <filter> <property value="concept"/> <op value="is-a"/> <value value="418038007"/> </filter> </include> <include> <system value="http://snomed.info/sct"/> <filter> <property value="concept"/> <op value="is-a"/> <value value="267425008"/> </filter> </include> <include> <system value="http://snomed.info/sct"/> <filter> <property value="concept"/> <op value="is-a"/> <value value="29736007"/> </filter> </include> <include> <system value="http://snomed.info/sct"/> <filter> <property value="concept"/> <op value="is-a"/> <value value="340519003"/> </filter> </include> <include> <system value="http://snomed.info/sct"/> <filter> <property value="concept"/> <op value="is-a"/> <value value="190753003"/> </filter> </include> <include> <system value="http://snomed.info/sct"/> <filter> <property value="concept"/> <op value="is-a"/> <value value="413427002"/> </filter> </include> <include> <system value="http://snomed.info/sct"/> <filter> <property value="concept"/> <op value="is-a"/> <value value="716186003"/> </filter> </include> </compose> </ValueSet>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.