Release 4B Snapshot #1

This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Servicerequest-example-colonoscopy-bx.xml

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Example of an order for a biopsy procedure that was part of a colonoscopy (id = "colon-biopsy")

<?xml version="1.0" encoding="UTF-8"?>

<ServiceRequest xmlns="http://hl7.org/fhir">
  <id value="colon-biopsy"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <div> <p> Resource &quot;colon-biopsy&quot; </p> </div> <p> <b> identifier</b> : id: 12345</p> <p> <b> requisition</b> : id: req12345</p> <p> <b> status</b> : completed</p> <p> <b> intent</b> : order</p> <p> <b> code</b> : Biopsy of colon <span>  (<a> SNOMED CT</a> #76164006 &quot;Biopsy of colon (procedure)&quot;)</span> </p> <p> <b> subject</b> : <a> Patient/example</a>  &quot;Peter CHALMERS&quot;</p> <p> <b> authoredOn</b> : 2017-03-05</p> <p> <b> requester</b> : <a> Practitioner/3ad0687e-f477-468c-afd5-fcc2bf897809: Dr. Beverly Crusher</a> </p> <p> <b> performer</b> : <a> Practitioner/example: Dr Adam Careful</a>  &quot;Adam CAREFUL&quot;</p> </div> </text> <identifier> 
    <value value="12345"/> 
  </identifier> 
  <!--    Example of biopsy service request that is part of a colonoscopy   -->
  <requisition> 
    <system value="http://bumc.org/requisitions"/> 
    <value value="req12345"/> 
  </requisition> 
  <status value="completed"/> 
  <intent value="order"/> 
  <code> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="76164006"/> 
      <display value="Biopsy of colon (procedure)"/> 
    </coding> 
    <text value="Biopsy of colon"/> 
  </code> 
  <subject> 
    <reference value="Patient/example"/> 
  </subject> 
  <authoredOn value="2017-03-05"/> 
  <requester> 

      <reference value="Practitioner/3ad0687e-f477-468c-afd5-fcc2bf897809"/> 
      <display value="Dr. Beverly Crusher"/> 

  </requester> 
  <performer> 
    <reference value="Practitioner/example"/> 
    <display value="Dr Adam Careful"/> 
  </performer> 
</ServiceRequest> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.