This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Patient Care Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Example of a device manipulation
{ "resourceType": "Procedure", "id": "example-implant", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div><p>Resource "example-implant" </p></div><p><b>status</b>: completed</p><p><b>code</b>: Implant Pacemaker <span> (<a>SNOMED CT</a>#25267002 "Insertion of intracardiac pacemaker (procedure)")</span></p><p><b>subject</b>: <a>Patient/example</a> "Peter CHALMERS"</p><p><b>performed</b>: 2015-04-05</p><h3>Performers</h3><table><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a>Practitioner/example: Dr Cecil Surgeon</a> "Adam CAREFUL"</td></tr></table><p><b>reasonCode</b>: Bradycardia <span> ()</span></p><p><b>followUp</b>: ROS 5 days - 2013-04-10 <span> ()</span></p><p><b>note</b>: Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p><h3>FocalDevices</h3><table><tr><td>-</td><td><b>Action</b></td><td><b>Manipulated</b></td></tr><tr><td>*</td><td>Implanted <span> (<a>Procedure Device Action Codes</a>#implanted)</span></td><td><a>Device/example-pacemaker</a></td></tr></table></div>" }, "status": "completed", "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "25267002", "display": "Insertion of intracardiac pacemaker (procedure)" } ], "text": "Implant Pacemaker" }, "subject": { "reference": "Patient/example" }, "performedDateTime": "2015-04-05", "performer": [ { "actor": { "reference": "Practitioner/example", "display": "Dr Cecil Surgeon" } } ], "reasonCode": [ { "text": "Bradycardia" } ], "followUp": [ { "text": "ROS 5 days - 2013-04-10" } ], "note": [ { "text": "Routine Appendectomy. Appendix was inflamed and in retro-caecal position" } ], "focalDevice": [ { "action": { "coding": [ { "system": "http://hl7.org/fhir/device-action", "code": "implanted" } ] }, "manipulated": { "reference": "Device/example-pacemaker" } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.