This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3 R2
| Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Oxygen Saturation by Pulse Oximetry Example (DeviceMetricObservation profile)
{
"resourceType": "Observation",
"id": "satO2",
"meta": {
"profile": [
"http://hl7.org/fhir/StructureDefinition/vitalsigns"
]
},
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div><p>Resource "satO2" </p><p>Profile: <a>Vital Signs Profile</a></p></div><p><b>identifier</b>: id: o1223435-10</p><p><b>partOf</b>: <a>Procedure/ob</a></p><p><b>status</b>: final</p><p><b>category</b>: Vital Signs <span> (<a>Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Oxygen saturation in Arterial blood <span> (<a>LOINC</a>#2708-6; <a>LOINC</a>#59408-5 "Oxygen saturation in Arterial blood by Pulse oximetry"; <a>ISO 11073-10101 Health informatics - Point-of-care</a>#150456 "MDC_PULS_OXIM_SAT_O2")</span></p><p><b>subject</b>: <a>Patient/example</a> "Peter CHALMERS"</p><p><b>effective</b>: 2014-12-05T09:30:10+01:00</p><p><b>value</b>: 95 %<span> (Details: UCUM code % = '%')</span></p><p><b>interpretation</b>: Normal (applies to non-numeric results) <span> (<a>ObservationInterpretation</a>#N "Normal")</span></p><p><b>device</b>: <a>DeviceMetric/example</a></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>90 %<span> (Details: UCUM code % = '%')</span></td><td>99 %<span> (Details: UCUM code % = '%')</span></td></tr></table></div>"
},
"identifier": [
{
"system": "http://goodcare.org/observation/id",
"value": "o1223435-10"
}
],
"partOf": [
{
"reference": "Procedure/ob"
}
],
"status": "final",
"category": [
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/observation-category",
"code": "vital-signs",
"display": "Vital Signs"
}
],
"text": "Vital Signs"
}
],
"code": {
"coding": [
{
"system": "http://loinc.org",
"code": "2708-6",
"display": "Oxygen saturation in Arterial blood"
},
{
"system": "http://loinc.org",
"code": "59408-5",
"display": "Oxygen saturation in Arterial blood by Pulse oximetry"
},
{
"system": "urn:iso:std:iso:11073:10101",
"code": "150456",
"display": "MDC_PULS_OXIM_SAT_O2"
}
]
},
"subject": {
"reference": "Patient/example"
},
"effectiveDateTime": "2014-12-05T09:30:10+01:00",
"valueQuantity": {
"value": 95,
"unit": "%",
"system": "http://unitsofmeasure.org",
"code": "%"
},
"interpretation": [
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
"code": "N",
"display": "Normal"
}
],
"text": "Normal (applies to non-numeric results)"
}
],
"device": {
"reference": "DeviceMetric/example"
},
"referenceRange": [
{
"low": {
"value": 90,
"unit": "%",
"system": "http://unitsofmeasure.org",
"code": "%"
},
"high": {
"value": 99,
"unit": "%",
"system": "http://unitsofmeasure.org",
"code": "%"
}
}
]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.