Release 4B Snapshot #1

This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Guidanceresponse-example.xml

Clinical Decision Support Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Not linked to any defined compartments

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Example of guidanceresponse (id = "example")

<?xml version="1.0" encoding="UTF-8"?>

<GuidanceResponse xmlns="http://hl7.org/fhir">
  <id value="example"/> 
  <!--    This example demonstrates the response to an $evaluate operation using the GuidanceResponse
   resource.    -->
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <div> <p> Resource &quot;example&quot; </p> </div> <p> <b> requestIdentifier</b> : id: guidanceRequest1</p> <p> <b> identifier</b> : id: guidanceResponse1</p> <p> <b> module</b> : <a> http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a> </p> <p> <b> status</b> : success</p> <p> <b> subject</b> : <a> Patient/example</a>  &quot;Peter CHALMERS&quot;</p> <p> <b> encounter</b> : <a> Encounter/example</a> </p> <p> <b> occurrenceDateTime</b> : 2017-03-10T16:02:00Z</p> <p> <b> performer</b> : <a> Device/software</a> </p> <p> <b> reasonCode</b> : Guideline Appropriate Ordering Assessment <span>  ()</span> </p> <p> <b> outputParameters</b> : <a>  </a> </p> <blockquote> <div> <p> Resource &quot;outputParameters1&quot; </p> </div> <blockquote> <p> <b> parameter</b> </p> <p> <b> name</b> : score</p> <p> <b> value</b> : 7</p> </blockquote> <blockquote> <p> <b> parameter</b> </p> <p> <b> name</b> : item-assessed</p> <p> <b> value</b> : CT, head, wo iv contrast <span>  (<a> Current Procedural Terminology (CPT®)</a> #70450)</span> </p> </blockquote> <blockquote> <p> <b> parameter</b> </p> <p> <b> name</b> : device</p> <p> <b> value</b> : <a> Device/software</a> </p> </blockquote> <blockquote> <p> <b> parameter</b> </p> <p> <b> name</b> : guideline-followed</p> <p> <b> value</b> : <a> http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a> </p> </blockquote> </blockquote> </div> </text> <contained> 
    <Parameters> 
      <id value="outputParameters1"/> 
      <parameter> 
        <name value="score"/> 
        <valueDecimal value="7"/> 
      </parameter> 
      <parameter> 
        <name value="item-assessed"/> 
    <valueCodeableConcept> 
      <coding> 
      <system value="http://www.ama-assn.org/go/cpt"/> 
      <code value="70450"/> 
      <display value="CT, head, wo iv contrast"/> 
      </coding> 
    </valueCodeableConcept> 
      </parameter> 
      <parameter> 
        <name value="device"/> 
        <valueReference> 
          <reference value="Device/software"/> 
        </valueReference> 
      </parameter> 
      <parameter> 
        <name value="guideline-followed"/> 
        <valueUri value="http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"/> 
      </parameter> 
    </Parameters> 
  </contained> 
  <requestIdentifier> 
    <system value="http://example.org"/> 
    <value value="guidanceRequest1"/> 
  </requestIdentifier> 
  <identifier> 
    <system value="http://example.org"/> 
    <value value="guidanceResponse1"/> 
  </identifier> 
  <moduleUri value="http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"/> 
  <status value="success"/> 
  <subject> 
    <reference value="Patient/example"/> 
  </subject> 
  <encounter> 
    <reference value="Encounter/example"/> 
  </encounter> 
  <occurrenceDateTime value="2017-03-10T16:02:00Z"/> 
  <performer> 
    <reference value="Device/software"/> 
  </performer> 
  <reasonCode> 
    <text value="Guideline Appropriate Ordering Assessment"/> 
  </reasonCode> 
  <outputParameters> 
    <reference value="#outputParameters1"/> 
  </outputParameters> 
</GuidanceResponse> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.