This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3
| Clinical Decision Support Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
Example of guidanceresponse
{
"resourceType": "GuidanceResponse",
"id": "example",
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div><p>Resource "example" </p></div><p><b>requestIdentifier</b>: id: guidanceRequest1</p><p><b>identifier</b>: id: guidanceResponse1</p><p><b>module</b>: <a>http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p><p><b>status</b>: success</p><p><b>subject</b>: <a>Patient/example</a> "Peter CHALMERS"</p><p><b>encounter</b>: <a>Encounter/example</a></p><p><b>occurrenceDateTime</b>: 2017-03-10T16:02:00Z</p><p><b>performer</b>: <a>Device/software</a></p><p><b>reasonCode</b>: Guideline Appropriate Ordering Assessment <span> ()</span></p><p><b>outputParameters</b>: <a> </a></p><blockquote><div><p>Resource "outputParameters1" </p></div><blockquote><p><b>parameter</b></p><p><b>name</b>: score</p><p><b>value</b>: 7</p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: item-assessed</p><p><b>value</b>: CT, head, wo iv contrast <span> (<a>Current Procedural Terminology (CPT®)</a>#70450)</span></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: device</p><p><b>value</b>: <a>Device/software</a></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: guideline-followed</p><p><b>value</b>: <a>http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p></blockquote></blockquote></div>"
},
"contained": [
{
"resourceType": "Parameters",
"id": "outputParameters1",
"parameter": [
{
"name": "score",
"valueDecimal": 7
},
{
"name": "item-assessed",
"valueCodeableConcept": {
"coding": [
{
"system": "http://www.ama-assn.org/go/cpt",
"code": "70450",
"display": "CT, head, wo iv contrast"
}
]
}
},
{
"name": "device",
"valueReference": {
"reference": "Device/software"
}
},
{
"name": "guideline-followed",
"valueUri": "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"
}
]
}
],
"requestIdentifier": {
"system": "http://example.org",
"value": "guidanceRequest1"
},
"identifier": [
{
"system": "http://example.org",
"value": "guidanceResponse1"
}
],
"moduleUri": "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html",
"status": "success",
"subject": {
"reference": "Patient/example"
},
"encounter": {
"reference": "Encounter/example"
},
"occurrenceDateTime": "2017-03-10T16:02:00Z",
"performer": {
"reference": "Device/software"
},
"reasonCode": [
{
"text": "Guideline Appropriate Ordering Assessment"
}
],
"outputParameters": {
"reference": "#outputParameters1"
}
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.