Release 4B Snapshot #1

This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Diagnosticreport-example-ultrasound.ttl

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner

Raw Turtle (+ also see Turtle/RDF Format Specification)

Abdominal Ultrasound example

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/DiagnosticReport/ultrasound> a fhir:DiagnosticReport;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "ultrasound"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2><span>Abdominal Ultrasound</span> (<span>Radiology</span>) </h2><table><tr><td>Subject</td><td><b>Jim </b> ?? 1974-12-25 ( Medical record number: 12345 (USUAL))</td></tr><tr><td>When For</td><td>2012-12-01T12:00:00+01:00</td></tr><tr><td>Reported</td><td>2012-12-01T12:00:00+01:00</td></tr></table><p><b>Report Details</b></p><p>Unremarkable study</p></div>"
  ];
  fhir:DiagnosticReport.status [ fhir:value "final"];
  fhir:DiagnosticReport.category [
     fhir:index 0;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:394914008;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "394914008" ];
       fhir:Coding.display [ fhir:value "Radiology" ]
     ], [
       fhir:index 1;
       fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/v2-0074" ];
       fhir:Coding.code [ fhir:value "RAD" ]
     ]
  ];
  fhir:DiagnosticReport.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:45036003;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "45036003" ];
       fhir:Coding.display [ fhir:value "Ultrasonography of abdomen" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Abdominal Ultrasound" ]
  ];
  fhir:DiagnosticReport.subject [
     fhir:link <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ]
  ];
  fhir:DiagnosticReport.effectiveDateTime [ fhir:value "2012-12-01T12:00:00+01:00"^^xsd:dateTime];
  fhir:DiagnosticReport.issued [ fhir:value "2012-12-01T12:00:00+01:00"^^xsd:dateTime];
  fhir:DiagnosticReport.performer [
     fhir:index 0;
     fhir:link <http://hl7.org/fhir/Practitioner/example>;
     fhir:Reference.reference [ fhir:value "Practitioner/example" ]
  ];
  fhir:DiagnosticReport.media [
     fhir:index 0;
     fhir:DiagnosticReport.media.comment [ fhir:value "A comment about the image" ];
     fhir:DiagnosticReport.media.link [
       fhir:link <http://hl7.org/fhir/Media/1.2.840.11361907579238403408700.3.1.04.19970327150033>;
       fhir:Reference.reference [ fhir:value "Media/1.2.840.11361907579238403408700.3.1.04.19970327150033" ];
       fhir:Reference.display [ fhir:value "WADO example image" ]
     ]
  ];
  fhir:DiagnosticReport.conclusion [ fhir:value "Unremarkable study"] .

<http://hl7.org/fhir/Patient/example> a fhir:Patient .

<http://hl7.org/fhir/Practitioner/example> a fhir:Practitioner .

<http://hl7.org/fhir/Media/1.2.840.11361907579238403408700.3.1.04.19970327150033> a fhir:Media .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/DiagnosticReport/ultrasound.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://build.fhir.org/DiagnosticReport/ultrasound.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.