Release 4B Snapshot #1

This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Devicerequest-example-insulinpump.json

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner

Raw JSON (canonical form + also see JSON Format Specification)

Insulin Pump request

{
  "resourceType": "DeviceRequest",
  "id": "insulinpump",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div><p>Resource &quot;insulinpump&quot; </p></div><p><b>identifier</b>: id: ip_request1.1</p><p><b>instantiatesCanonical</b>: <a>http://motivemi.com/artifacts/PlanDefinition/low-suicide-risk-order-set</a></p><p><b>basedOn</b>: <span>: Homecare - DM follow-up</span></p><p><b>priorRequest</b>: <span>: CGM ambulatory</span></p><p><b>groupIdentifier</b>: id: ip_request1</p><p><b>status</b>: active</p><p><b>intent</b>: instance-order</p><p><b>priority</b>: routine</p><p><b>code</b>: Insulin delivery device panel <span> (<a>LOINC</a>#43148-6)</span></p><p><b>subject</b>: <a>Patient/dicom</a> &quot; MINT_TEST&quot;</p><p><b>encounter</b>: <span>: Encounter 1</span></p><p><b>occurrence</b>: 2013-05-08T09:33:27+07:00</p><p><b>authoredOn</b>: 2013-05-08T09:33:27+07:00</p><p><b>requester</b>: <a>Practitioner/example: Dr. Adam Careful</a> &quot;Adam CAREFUL&quot;</p><p><b>performerType</b>: Nurse <span> ([not stated] &quot;Qualified nurse&quot;)</span></p><p><b>performer</b>: <span>: Nurse Rossignol</span></p><p><b>reasonCode</b>: gastroparesis <span> ()</span></p><p><b>reasonReference</b>: <span>: Gastroparesis</span></p><p><b>supportingInfo</b>: <span>: Previous results</span></p><p><b>note</b>: this is the right device brand and model</p><p><b>relevantHistory</b>: <span>: Request for unspecified device</span></p></div>"
  },
  "identifier": [
    {
      "value": "ip_request1.1"
    }
  ],
  "instantiatesCanonical": [
    "http://motivemi.com/artifacts/PlanDefinition/low-suicide-risk-order-set"
  ],
  "basedOn": [
    {
      "display": "Homecare - DM follow-up"
    }
  ],
  "priorRequest": [
    {
      "display": "CGM ambulatory"
    }
  ],
  "groupIdentifier": {
    "value": "ip_request1"
  },
  "status": "active",
  "intent": "instance-order",
  "priority": "routine",
  "codeCodeableConcept": {
    "coding": [
      {
        "system": "http://loinc.org",
        "code": "43148-6"
      }
    ],
    "text": "Insulin delivery device panel"
  },
  "subject": {
    "reference": "Patient/dicom"
  },
  "encounter": {
    "display": "Encounter 1"
  },
  "occurrenceDateTime": "2013-05-08T09:33:27+07:00",
  "authoredOn": "2013-05-08T09:33:27+07:00",
  "requester": {
    "reference": "Practitioner/example",
    "display": "Dr. Adam Careful"
  },
  "performerType": {
    "coding": [
      {
        "display": "Qualified nurse"
      }
    ],
    "text": "Nurse"
  },
  "performer": {
    "display": "Nurse Rossignol"
  },
  "reasonCode": [
    {
      "text": "gastroparesis"
    }
  ],
  "reasonReference": [
    {
      "display": "Gastroparesis"
    }
  ],
  "supportingInfo": [
    {
      "display": "Previous results"
    }
  ],
  "note": [
    {
      "text": "this is the right device brand and model"
    }
  ],
  "relevantHistory": [
    {
      "display": "Request for unspecified device"
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.