This page is part of the FHIR Specification (v4.3.0-snapshot1: Release 4B Snapshot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4B R4 R3
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative |
Raw JSON (canonical form + also see JSON Format Specification)
Definition for Code System DataAbsentReason
{ "resourceType" : "CodeSystem", "id" : "data-absent-reason", "meta" : { "lastUpdated" : "2021-12-20T14:08:35.086+11:00" }, "text" : { "status" : "extensions", "div" : "<div>!-- Snipped for Brevity --></div>" }, "extension" : [{ "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode" : "oo" }, { "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status", "valueCode" : "normative" }, { "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-normative-version", "valueCode" : "4.0.0" }, { "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm", "valueInteger" : 5 }], "url" : "http://terminology.hl7.org/CodeSystem/data-absent-reason", "identifier" : [{ "system" : "urn:ietf:rfc:3986", "value" : "urn:oid:2.16.840.1.113883.4.642.1.1048" }], "version" : "4.3.0-snapshot1", "name" : "DataAbsentReason", "title" : "DataAbsentReason", "status" : "active", "experimental" : false, "date" : "2021-12-20T14:08:35+11:00", "description" : "Used to specify why the normally expected content of the data element is missing.", "caseSensitive" : true, "valueSet" : "http://hl7.org/fhir/ValueSet/data-absent-reason", "content" : "complete", "concept" : [{ "code" : "unknown", "display" : "Unknown", "definition" : "The value is expected to exist but is not known.", "concept" : [{ "code" : "asked-unknown", "display" : "Asked But Unknown", "definition" : "The source was asked but does not know the value." }, { "code" : "temp-unknown", "display" : "Temporarily Unknown", "definition" : "There is reason to expect (from the workflow) that the value may become known." }, { "code" : "not-asked", "display" : "Not Asked", "definition" : "The workflow didn't lead to this value being known." }, { "code" : "asked-declined", "display" : "Asked But Declined", "definition" : "The source was asked but declined to answer." }] }, { "extension" : [{ "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments", "valueString" : "Using \"masked\" may be breach of security or confidentiality, but there are times when its use is required to support alternate workflows for gaining access to denied information." }], "code" : "masked", "display" : "Masked", "definition" : "The information is not available due to security, privacy or related reasons." }, { "code" : "not-applicable", "display" : "Not Applicable", "definition" : "There is no proper value for this element (e.g. last menstrual period for a male)." }, { "code" : "unsupported", "display" : "Unsupported", "definition" : "The source system wasn't capable of supporting this element." }, { "extension" : [{ "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments", "valueString" : "It may be linked by internal references (e.g. xml:id). This usually implies that the value could not be represented in the correct format - this may be due to system limitations, or this particular data value." }], "code" : "as-text", "display" : "As Text", "definition" : "The content of the data is represented in the resource narrative." }, { "code" : "error", "display" : "Error", "definition" : "Some system or workflow process error means that the information is not available.", "concept" : [{ "extension" : [{ "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments", "valueString" : "This is sometimes an output value from measuring devices." }], "code" : "not-a-number", "display" : "Not a Number (NaN)", "definition" : "The numeric value is undefined or unrepresentable due to a floating point processing error." }, { "extension" : [{ "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments", "valueString" : "This is sometimes an output value from measuring devices." }], "code" : "negative-infinity", "display" : "Negative Infinity (NINF)", "definition" : "The numeric value is excessively low and unrepresentable due to a floating point processing error." }, { "extension" : [{ "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments", "valueString" : "This is sometimes an output value from measuring devices." }], "code" : "positive-infinity", "display" : "Positive Infinity (PINF)", "definition" : "The numeric value is excessively high and unrepresentable due to a floating point processing error." }] }, { "code" : "not-performed", "display" : "Not Performed", "definition" : "The value is not available because the observation procedure (test, etc.) was not performed." }, { "extension" : [{ "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments", "valueString" : "This is most often associated with required bindings that do not include the actual code used, but may be used with other data types." }], "code" : "not-permitted", "display" : "Not Permitted", "definition" : "The value is not permitted in this context (e.g. due to profiles, or the base data types)." }] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.