Release 5 Ballot

This page is part of the FHIR Specification (v5.0.0-ballot: R5 Ballot - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Example Procedure/f001 (JSON)

Patient Care Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Encounter, Patient, Practitioner, RelatedPerson

Raw JSON (canonical form + also see JSON Format Specification)

Real-world procedure example

{
  "resourceType": "Procedure",
  "id": "f001",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Procedure</b><a name=\"f001\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Procedure &quot;f001&quot; </p></div><p><b>status</b>: completed</p><p><b>code</b>: Heart valve replacement <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#34068001)</span></p><p><b>subject</b>: <a href=\"patient-example-f001-pieter.html\">Patient/f001: P. van de Heuvel</a> &quot;Pieter VAN DE HEUVEL&quot;</p><p><b>encounter</b>: <a href=\"encounter-example-f001-heart.html\">Encounter/f001</a></p><p><b>occurrence</b>: 2011-06-26 --&gt; 2011-06-27</p><h3>Performers</h3><table class=\"grid\"><tr><td>-</td><td><b>Function</b></td><td><b>Actor</b></td></tr><tr><td>*</td><td>Care role <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (unknown#01.000 &quot;Arts&quot;)</span></td><td><a href=\"practitioner-example-f002-pv.html\">Practitioner/f002: P. Voigt</a> &quot;Pieter VOIGT&quot;</td></tr></table><h3>Reasons</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td></tr><tr><td>*</td><td>Heart valve disorder <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></td></tr></table><p><b>bodySite</b>: Heart valve structure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#17401000)</span></p><p><b>outcome</b>: improved blood circulation <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><p><b>report</b>: <a href=\"diagnosticreport-example-f001-bloodexam.html\">DiagnosticReport/f001: Lab results blood test</a></p><p><b>followUp</b>: described in care plan <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p></div>"
  },
  "status": "completed",
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "34068001",
        "display": "Heart valve replacement"
      }
    ]
  },
  "subject": {
    "reference": "Patient/f001",
    "display": "P. van de Heuvel"
  },
  "encounter": {
    "reference": "Encounter/f001"
  },
  "occurrencePeriod": {
    "start": "2011-06-26",
    "end": "2011-06-27"
  },
  "performer": [
    {
      "function": {
        "coding": [
          {
            "system": "urn:oid:2.16.840.1.113883.2.4.15.111",
            "code": "01.000",
            "display": "Arts"
          }
        ],
        "text": "Care role"
      },
      "actor": {
        "reference": "Practitioner/f002",
        "display": "P. Voigt"
      }
    }
  ],
  "reason": [
    {
      "concept": {
        "text": "Heart valve disorder"
      }
    }
  ],
  "bodySite": [
    {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "17401000",
          "display": "Heart valve structure"
        }
      ]
    }
  ],
  "outcome": {
    "text": "improved blood circulation"
  },
  "report": [
    {
      "reference": "DiagnosticReport/f001",
      "display": "Lab results blood test"
    }
  ],
  "followUp": [
    {
      "text": "described in care plan"
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.