Release 5 Ballot

This page is part of the FHIR Specification (v5.0.0-ballot: R5 Ballot - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Example Observation/satO2 (Narrative)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile Observation.


Generated Narrative: Observation

Resource Observation "satO2"

Profile: Vital Signs Profile

identifier: id: o1223435-10

partOf: Procedure/ob

status: final

category: Vital Signs (Observation Category Codes#vital-signs)

code: Oxygen saturation in Arterial blood (LOINC#2708-6; LOINC#59408-5 "Oxygen saturation in Arterial blood by Pulse oximetry"; ISO 11073-10101 Health informatics - Point-of-care#150456 "MDC_PULS_OXIM_SAT_O2")

subject: Patient/example "Peter CHALMERS"

effective: 2014-12-05T09:30:10+01:00

value: 95 % (Details: UCUM code % = '%')

interpretation: Normal (applies to non-numeric results) (ObservationInterpretation#N "Normal")

device: DeviceMetric/example

ReferenceRanges

-LowHigh
*90 % (Details: UCUM code % = '%')99 % (Details: UCUM code % = '%')

 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.