This page is part of the FHIR Specification (v5.0.0-ballot: R5 Ballot - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner |
This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile MedicationRequest.
Generated Narrative: MedicationRequest
Resource MedicationRequest "medrx0301"
identifier: id: 12345689 (OFFICIAL)
status: completed
statusReason: Try another treatment first (MedicationRequest Status Reason Codes#altchoice)
intent: order
category: Inpatient (Medication request administration location codes#inpatient)
- | Reference |
* |
|
subject: Patient/pat1: Donald Duck "Donald DUCK"
encounter: Encounter/f201: encounter who leads to this prescription
supportingInformation: Procedure/biopsy
authoredOn: 2015-01-15
requester: Practitioner/f007: Patrick Pump "Simone HEPS"
performerType: Public Health Nurse (SNOMED CT#26369006)
performer: Practitioner/f204: Carla Espinosa "Carla Espinosa"
- | Concept |
* | Rib Pain (finding) (SNOMED CT#297217002) |
insurance: Coverage/9876B1
note: Patient told to take with food
dose
dosageInstruction
sequence: 1
text: one to two tablets every 4-6 hours as needed for rib pain
additionalInstruction: Warning. May cause drowsiness. If affected do not drive or operate machinery. Avoid alcoholic drink (qualifier value) (SNOMED CT#418914006)
patientInstruction: Take one to two tablets every four to six hours as needed for rib pain
timing: Do Once per 4-6 hours
asNeededFor: Rib Pain (finding) (SNOMED CT#297217002)
route: Oral Route (SNOMED CT#26643006)
method: Swallow - dosing instruction imperative (qualifier value) (SNOMED CT#421521009)
dispenseRequest
validityPeriod: 2015-01-15 --> 2016-01-15
numberOfRepeatsAllowed: 0
quantity: 30 TAB (Details: http://terminology.hl7.org/CodeSystem/v3-orderableDrugForm code TAB = 'Tablet')
ExpectedSupplyDurations
- Value Unit System Code * 10 days Unified Code for Units of Measure (UCUM) d dispenser: Organization/2.16.840.1.113883.19.5 "Good Health Clinic"
- | Allowed[x] | Reason |
* | true | formulary policy (ActReason#FP) |
target: ServiceRequest/physiotherapy
recorded: 02/02/2017 4:23:07 AM
Agents
- Role Who * author (originator) (ParticipationType#AUT) Practitioner/example: Dr Adam Careful "Adam CAREFUL" Signatures
- Type When Who TargetFormat SigFormat Data * Author's Signature (Details: urn:iso-astm:E1762-95:2013 code 1.2.840.10065.1.12.1.1 = 'Author's Signature', stated as 'Author's Signature') 02/02/2017 4:23:07 AM Practitioner/example: Dr Adam Careful "Adam CAREFUL" application/fhir+xml application/signature+xml dGhpcyBibG9iIGlzIHNuaXBwZWQ=
Other examples that reference this example:
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.