NoninBlePulseOx (id = "NoninBlePulseOx")
<?xml version="1.0" encoding="UTF-8"?> <Device xmlns="http://hl7.org/fhir"> <id value="NoninBlePulseOx"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="NoninBlePulseOx"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device "NoninBlePulseOx" </p> </div> <p> <b> identifier</b> : System Identifier: 74-E8-FF-FE-FF-05-1C-00, Bluetooth Address: 00-1C-05-FF-E8-74</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td> *</td> <td> 120359741556</td> <td> <a href="http://hl7.org/fhir/NamingSystem/gs1-di">http://hl7.org/fhir/NamingSystem/gs1-di</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> (01)120359741556(21)501900083</td> <td> unknown</td> </tr> </table> <p> <b> manufacturer</b> : Nonin_Medical_Inc.</p> <p> <b> serialNumber</b> : 501900083</p> <h3> DeviceNames</h3> <table class="grid"><tr> <td> -</td> <td> <b> Name</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> Nonin3230_501900083</td> <td> user-friendly-name</td> </tr> </table> <p> <b> modelNumber</b> : Model 3230</p> <p> <b> type</b> : MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #65573 "MDC_MOC_VMS_MDS_SIMP")</span> </p> <blockquote> <p> <b> version</b> </p> <p> <b> type</b> : MDC_ID_PROD_SPEC_FW: Firmware revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #531976)</span> </p> <p> <b> value</b> : r2.1</p> </blockquote> <blockquote> <p> <b> version</b> </p> <p> <b> type</b> : MDC_ID_PROD_SPEC_SW: Software revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #531975)</span> </p> <p> <b> value</b> : r1.5 9.7</p> </blockquote> <blockquote> <p> <b> version</b> </p> <p> <b> type</b> : MDC_ID_PROD_SPEC_HW: Hardware revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #531974)</span> </p> <p> <b> value</b> : r1.0</p> </blockquote> <blockquote> <p> <b> version</b> </p> <p> <b> type</b> : MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532352)</span> </p> <p> <b> value</b> : 6.0</p> </blockquote> <h3> Specializations</h3> <table class="grid"><tr> <td> -</td> <td> <b> SystemType</b> </td> <td> <b> Version</b> </td> </tr> <tr> <td> *</td> <td> MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528388)</span> </td> <td> 1</td> </tr> </table> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532353)</span> </p> <p> <b> value</b> : 4 <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ContinuaPAN#4)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : regulation-status <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#532354.0)</span> </p> <p> <b> value</b> : Device is Regulated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#N)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #68220)</span> </p> <p> <b> value</b> : MDC_TIME_SYNC_NONE: No time synchronization <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532224)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : mds-time-capab-real-time-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#68219.0)</span> </p> <p> <b> value</b> : real time clock supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#Y)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : mds-time-capab-set-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#68219.1)</span> </p> <p> <b> value</b> : setting the time supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#Y)</span> </p> </blockquote> </div> </text> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="SYSID"/> <display value="System Identifier"/> </coding> </type> <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> <value value="74-E8-FF-FE-FF-05-1C-00"/> </identifier> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="BTMAC"/> <display value="Bluetooth Address"/> </coding> </type> <system value="http://hl7.org/fhir/sid/eui-48"/> <value value="00-1C-05-FF-E8-74"/> </identifier> <udiCarrier> <deviceIdentifier value="120359741556"/> <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> <carrierHRF value="(01)120359741556(21)501900083"/> <entryType value="unknown"/> </udiCarrier> <manufacturer value="Nonin_Medical_Inc."/> <serialNumber value="501900083"/> <deviceName> <name value="Nonin3230_501900083"/> <type value="user-friendly-name"/> </deviceName> <modelNumber value="Model 3230"/> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="65573"/> <display value="MDC_MOC_VMS_MDS_SIMP"/> </coding> <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> </type> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531976"/> </coding> <text value="MDC_ID_PROD_SPEC_FW: Firmware revision"/> </type> <value value="r2.1"/> </version> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531975"/> </coding> <text value="MDC_ID_PROD_SPEC_SW: Software revision"/> </type> <value value="r1.5 9.7"/> </version> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531974"/> </coding> <text value="MDC_ID_PROD_SPEC_HW: Hardware revision"/> </type> <value value="r1.0"/> </version> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532352"/> </coding> <text value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/> </type> <value value="6.0"/> </version> <specialization> <systemType> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528388"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"/> </systemType> <version value="1"/> </specialization> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532353"/> </coding> <text value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaPAN"/> <code value="4"/> </coding> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="532354.0"/> </coding> <text value="regulation-status"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="N"/> </coding> <text value="Device is Regulated"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="68220"/> </coding> <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> </type> <valueCodeableConcept> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532224"/> </coding> <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="68219.0"/> </coding> <text value="mds-time-capab-real-time-clock"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="Y"/> </coding> <text value="real time clock supported"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="68219.1"/> </coding> <text value="mds-time-capab-set-clock"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="Y"/> </coding> <text value="setting the time supported"/> </valueCodeableConcept> </property> </Device>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 Ballot hl7.fhir.core#5.0.0-ballot generated on Sat, Sep 10, 2022 05:02+1000.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4B |
Compare to R5 Draft |
|
Propose a change