Release 5 Ballot

This page is part of the FHIR Specification (v5.0.0-ballot: R5 Ballot - see ballot notes). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Example Device/NoninBlePulseOx (JSON)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

Raw JSON (canonical form + also see JSON Format Specification)

NoninBlePulseOx

{
  "resourceType": "Device",
  "id": "NoninBlePulseOx",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"NoninBlePulseOx\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device &quot;NoninBlePulseOx&quot; </p></div><p><b>identifier</b>: System Identifier: 74-E8-FF-FE-FF-05-1C-00, Bluetooth Address: 00-1C-05-FF-E8-74</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>120359741556</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)120359741556(21)501900083</td><td>unknown</td></tr></table><p><b>manufacturer</b>: Nonin_Medical_Inc.</p><p><b>serialNumber</b>: 501900083</p><h3>DeviceNames</h3><table class=\"grid\"><tr><td>-</td><td><b>Name</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>Nonin3230_501900083</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: Model 3230</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 &quot;MDC_MOC_VMS_MDS_SIMP&quot;)</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></p><p><b>value</b>: r2.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975)</span></p><p><b>value</b>: r1.5 9.7</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974)</span></p><p><b>value</b>: r1.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352)</span></p><p><b>value</b>: 6.0</p></blockquote><h3>Specializations</h3><table class=\"grid\"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528388)</span></td><td>1</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>value</b>: 4 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaPAN#4)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#532354.0)</span></p><p><b>value</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>value</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.0)</span></p><p><b>value</b>: real time clock supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.1)</span></p><p><b>value</b>: setting the time supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote></div>"
  },
  "identifier": [
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
            "code": "SYSID",
            "display": "System Identifier"
          }
        ]
      },
      "system": "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
      "value": "74-E8-FF-FE-FF-05-1C-00"
    },
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
            "code": "BTMAC",
            "display": "Bluetooth Address"
          }
        ]
      },
      "system": "http://hl7.org/fhir/sid/eui-48",
      "value": "00-1C-05-FF-E8-74"
    }
  ],
  "udiCarrier": [
    {
      "deviceIdentifier": "120359741556",
      "issuer": "http://hl7.org/fhir/NamingSystem/gs1-di",
      "jurisdiction": "http://hl7.org/fhir/NamingSystem/fda-udi",
      "carrierHRF": "(01)120359741556(21)501900083",
      "entryType": "unknown"
    }
  ],
  "manufacturer": "Nonin_Medical_Inc.",
  "serialNumber": "501900083",
  "deviceName": [
    {
      "name": "Nonin3230_501900083",
      "type": "user-friendly-name"
    }
  ],
  "modelNumber": "Model 3230",
  "type": [
    {
      "coding": [
        {
          "system": "urn:iso:std:iso:11073:10101",
          "code": "65573",
          "display": "MDC_MOC_VMS_MDS_SIMP"
        }
      ],
      "text": "MDC_MOC_VMS_MDS_SIMP: Personal Health Device"
    }
  ],
  "version": [
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "531976"
          }
        ],
        "text": "MDC_ID_PROD_SPEC_FW: Firmware revision"
      },
      "value": "r2.1"
    },
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "531975"
          }
        ],
        "text": "MDC_ID_PROD_SPEC_SW: Software revision"
      },
      "value": "r1.5 9.7"
    },
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "531974"
          }
        ],
        "text": "MDC_ID_PROD_SPEC_HW: Hardware revision"
      },
      "value": "r1.0"
    },
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "532352"
          }
        ],
        "text": "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
      },
      "value": "6.0"
    }
  ],
  "specialization": [
    {
      "systemType": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "528388"
          }
        ],
        "text": "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"
      },
      "version": "1"
    }
  ],
  "property": [
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "532353"
          }
        ],
        "text": "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"
      },
      "valueCodeableConcept": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/ContinuaPAN",
            "code": "4"
          }
        ]
      }
    },
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
            "code": "532354.0"
          }
        ],
        "text": "regulation-status"
      },
      "valueCodeableConcept": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/v2-0136",
            "code": "N"
          }
        ],
        "text": "Device is Regulated"
      }
    },
    {
      "type": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "68220"
          }
        ],
        "text": "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
      },
      "valueCodeableConcept": {
        "coding": [
          {
            "system": "urn:iso:std:iso:11073:10101",
            "code": "532224"
          }
        ],
        "text": "MDC_TIME_SYNC_NONE: No time synchronization"
      }
    },
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
            "code": "68219.0"
          }
        ],
        "text": "mds-time-capab-real-time-clock"
      },
      "valueCodeableConcept": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/v2-0136",
            "code": "Y"
          }
        ],
        "text": "real time clock supported"
      }
    },
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
            "code": "68219.1"
          }
        ],
        "text": "mds-time-capab-set-clock"
      },
      "valueCodeableConcept": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/v2-0136",
            "code": "Y"
          }
        ],
        "text": "setting the time supported"
      }
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.