AND20601BPMonitor
{
"resourceType": "Device",
"id": "and20601bpmonitor",
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"and20601bpmonitor\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "and20601bpmonitor" </p></div><p><b>identifier</b>: System Identifier: 00-09-1F-FF-FE-80-07-3A, Bluetooth Address: 00-09-1F-80-07-3A</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>39183189818</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)39183189818(21)5091100966</td><td>unknown</td></tr></table><p><b>manufacturer</b>: A&D Medical</p><p><b>serialNumber</b>: 5091100966</p><h3>DeviceNames</h3><table class=\"grid\"><tr><td>-</td><td><b>Name</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>AND BP UA-767PBT-C</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: UA-767PBT-C</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 "MDC_MOC_VMS_MDS_SIMP")</span></p><h3>Versions</h3><table class=\"grid\"><tr><td>-</td><td><b>Type</b></td><td><b>Value</b></td></tr><tr><td>*</td><td>MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352)</span></td><td>1.0</td></tr></table><h3>Specializations</h3><table class=\"grid\"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528391)</span></td><td>1</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>value</b>: 7 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaPAN#7)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#532354.0)</span></p><p><b>value</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>value</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.0)</span></p><p><b>value</b>: real time clock supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.1)</span></p><p><b>value</b>: setting the time supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-mgr-set-time <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.11)</span></p><p><b>value</b>: manager requested to set the time <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote></div>"
},
"identifier": [
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code": "SYSID",
"display": "System Identifier"
}
]
},
"system": "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value": "00-09-1F-FF-FE-80-07-3A"
},
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code": "BTMAC",
"display": "Bluetooth Address"
}
]
},
"system": "http://hl7.org/fhir/sid/eui-48",
"value": "00-09-1F-80-07-3A"
}
],
"udiCarrier": [
{
"deviceIdentifier": "39183189818",
"issuer": "http://hl7.org/fhir/NamingSystem/gs1-di",
"jurisdiction": "http://hl7.org/fhir/NamingSystem/fda-udi",
"carrierHRF": "(01)39183189818(21)5091100966",
"entryType": "unknown"
}
],
"manufacturer": "A&D Medical",
"serialNumber": "5091100966",
"deviceName": [
{
"name": "AND BP UA-767PBT-C",
"type": "user-friendly-name"
}
],
"modelNumber": "UA-767PBT-C",
"type": [
{
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "65573",
"display": "MDC_MOC_VMS_MDS_SIMP"
}
],
"text": "MDC_MOC_VMS_MDS_SIMP: Personal Health Device"
}
],
"version": [
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "532352"
}
],
"text": "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
},
"value": "1.0"
}
],
"specialization": [
{
"systemType": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "528391"
}
],
"text": "MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter"
},
"version": "1"
}
],
"property": [
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "532353"
}
],
"text": "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"
},
"valueCodeableConcept": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ContinuaPAN",
"code": "7"
}
]
}
},
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code": "532354.0",
"display": "regulation-status"
}
]
},
"valueCodeableConcept": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0136",
"code": "N"
}
],
"text": "Device is Regulated"
}
},
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "68220"
}
],
"text": "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
},
"valueCodeableConcept": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "532224"
}
],
"text": "MDC_TIME_SYNC_NONE: No time synchronization"
}
},
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code": "68219.0"
}
],
"text": "mds-time-capab-real-time-clock"
},
"valueCodeableConcept": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0136",
"code": "Y"
}
],
"text": "real time clock supported"
}
},
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code": "68219.1"
}
],
"text": "mds-time-capab-set-clock"
},
"valueCodeableConcept": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0136",
"code": "Y"
}
],
"text": "setting the time supported"
}
},
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code": "68219.11"
}
],
"text": "mds-time-mgr-set-time"
},
"valueCodeableConcept": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0136",
"code": "Y"
}
],
"text": "manager requested to set the time"
}
}
]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 Ballot hl7.fhir.core#5.0.0-ballot generated on Sat, Sep 10, 2022 05:02+1000.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4B |
Compare to R5 Draft |
|
Propose a change