example-udi1
{
"resourceType": "Device",
"id": "example-udi1",
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"example-udi1\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "example-udi1" </p></div><p><b>identifier</b>: 1234-5678-90AB-CDEF, Serial Number: 10987654d321</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierAIDC</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>00844588003288</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1\">http://hl7.org/fhir/NamingSystem/gs1</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH</td><td>{01}00844588003288{17}141120{10}7654321D{21}10987654d321</td><td>barcode</td></tr></table><p><b>status</b>: active</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>expirationDate</b>: 2014-11-20</p><p><b>lotNumber</b>: 7654321D</p><h3>DeviceNames</h3><table class=\"grid\"><tr><td>-</td><td><b>Name</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>PM/Octane 2014</td><td>user-friendly-name</td></tr></table><p><b>type</b>: Coated femoral stem prosthesis, modular <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#468063009)</span></p><h3>Associations</h3><table class=\"grid\"><tr><td>-</td><td><b>Status</b></td><td><b>HumanSubject</b></td></tr><tr><td>*</td><td>attached <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (device-association-status#attached)</span></td><td><a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</td></tr></table><p><b>safety</b>: MR Unsafe <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (unknown#mr-unsafe)</span></p></div>"
},
"identifier": [
{
"type": {
"coding": [
{
"system": "http://acme.com/devices/pacemakers/octane/serial"
}
]
},
"value": "1234-5678-90AB-CDEF"
},
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0203",
"code": "SNO"
}
]
},
"value": "10987654d321"
}
],
"udiCarrier": [
{
"deviceIdentifier": "00844588003288",
"issuer": "http://hl7.org/fhir/NamingSystem/gs1",
"jurisdiction": "http://hl7.org/fhir/NamingSystem/fda-udi",
"carrierAIDC": "XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH",
"carrierHRF": "{01}00844588003288{17}141120{10}7654321D{21}10987654d321",
"entryType": "barcode"
}
],
"status": "active",
"manufacturer": "Acme Devices, Inc",
"expirationDate": "2014-11-20",
"lotNumber": "7654321D",
"deviceName": [
{
"name": "PM/Octane 2014",
"type": "user-friendly-name"
}
],
"type": [
{
"coding": [
{
"system": "http://snomed.info/sct",
"code": "468063009",
"display": "Coated femoral stem prosthesis, modular"
}
],
"text": "Coated femoral stem prosthesis, modular"
}
],
"association": [
{
"status": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/device-association-status",
"code": "attached"
}
]
},
"humanSubject": {
"reference": "Patient/example"
}
}
],
"safety": [
{
"coding": [
{
"system": "urn:oid:2.16.840.1.113883.3.26.1.1",
"code": "mr-unsafe",
"display": "MR Unsafe"
}
],
"text": "MR Unsafe"
}
]
}
Usage note: every effort has been made to ensure that the
examples are correct and useful, but they are not a normative part
of the specification.