This page is part of the FHIR Specification (v4.6.0: R5 Draft Ballot). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Patient, Practitioner |
Raw JSON (canonical form + also see JSON Format Specification)
General Specimen Example
{ "resourceType": "Specimen", "id": "101", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>identifier</b>: id: 23234352356</p><p><b>accessionIdentifier</b>: id: X352356</p><p><b>status</b>: available</p><p><b>type</b>: <span>Venous blood specimen</span></p><p><b>subject</b>: <a>Peter Patient. Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410 5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a></p><p><b>receivedTime</b>: 4 Mar. 2011, 6:03:00 pm</p><p><b>request</b>: <a>Generated Summary: status: completed; intent: order; <span>Diagnostics Procedure</span>; <span>Computed tomography of head</span></a></p><h3>Collections</h3><table><tr><td>-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td><td><b>Quantity</b></td><td><b>Method</b></td><td><b>BodySite</b></td></tr><tr><td>*</td><td><a>Generated Summary: id: 23; active; Adam Careful </a></td><td>30 May 2011, 4:15:00 pm</td><td>6 mL</td><td><span>Line, Venous</span></td><td><span>Right median cubital vein</span></td></tr></table><h3>Containers</h3><table><tr><td>-</td><td><b>Identifier</b></td><td><b>Description</b></td><td><b>Type</b></td><td><b>Capacity</b></td><td><b>SpecimenQuantity</b></td><td><b>Additive[x]</b></td></tr><tr><td>*</td><td>id: 48736-15394-75465</td><td>Green Gel tube</td><td><span>Vacutainer</span></td><td>10 mL</td><td>6 mL</td><td><a> </a><blockquote><p><b>instance</b>: false</p><h3>Codes</h3><table><tr><td>-</td></tr><tr><td>*</td></tr></table></blockquote></td></tr></table><p><b>note</b>: Specimen is grossly lipemic</p></div>" }, "contained": [ { "resourceType": "Substance", "id": "hep", "instance": false, "code": { "concept": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/v3-EntityCode", "code": "HEPL" } ] } } } ], "identifier": [ { "system": "http://ehr.acme.org/identifiers/collections", "value": "23234352356" } ], "accessionIdentifier": { "system": "http://lab.acme.org/specimens/2011", "value": "X352356" }, "status": "available", "type": { "coding": [ { "system": "http://snomed.info/sct", "code": "122555007", "display": "Venous blood specimen" } ] }, "subject": { "reference": "Patient/example", "display": "Peter Patient" }, "receivedTime": "2011-03-04T07:03:00Z", "request": [ { "reference": "ServiceRequest/example" } ], "collection": { "collector": { "reference": "Practitioner/example" }, "collectedDateTime": "2011-05-30T06:15:00Z", "quantity": { "value": 6, "unit": "mL" }, "method": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/v2-0488", "code": "LNV" } ] }, "bodySite": { "coding": [ { "system": "http://snomed.info/sct", "code": "49852007", "display": "Structure of median cubital vein (body structure)" } ], "text": "Right median cubital vein" } }, "container": [ { "identifier": [ { "value": "48736-15394-75465" } ], "description": "Green Gel tube", "type": { "text": "Vacutainer" }, "capacity": { "value": 10, "unit": "mL" }, "specimenQuantity": { "value": 6, "unit": "mL" }, "additiveReference": { "reference": "#hep" } } ], "note": [ { "text": "Specimen is grossly lipemic" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.