This page is part of the FHIR Specification (v4.6.0: R5 Draft Ballot). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
Oxygen Saturation by Pulse Oximetry Example (DeviceMetricObservation profile) (id = "satO2")
<?xml version="1.0" encoding="UTF-8"?> <Observation xmlns="http://hl7.org/fhir"> <id value="satO2"/> <meta> <profile value="http://hl7.org/fhir/StructureDefinition/vitalsigns"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> identifier</b> : id: o1223435-10</p> <p> <b> partOf</b> : <a> Generated Summary: status: completed; <span> OB</span> ; <span> Vaginal delivery</span> ; occurrence: 2012-06-02; <span> delivery of healthy male infant</span> </a> </p> <p/> <p> <b> category</b> : <span> Vital Signs</span> </p> <p> <b> code</b> : <span> Oxygen saturation in Arterial blood</span> </p> <p> <b> subject</b> : <a> Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410 5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a> </p> <p> <b> effective</b> : 5 Dec. 2014, 7:30:10 pm</p> <p> <b> value</b> : 95 %</p> <p> <b> interpretation</b> : <span> Normal (applies to non-numeric results)</span> </p> <p> <b> device</b> : <a> Generated Summary: id: 345675; <span> MDC_PULS_OXIM_SAT_O2</span> ; <span> MDC_DIM_PERCENT</span> ; operationalStatus: on; color: blue; category: measurement; Do Once per 1 seconds</a> </p> <h3> ReferenceRanges</h3> <table> <tr> <td> -</td> <td> <b> Low</b> </td> <td> <b> High</b> </td> </tr> <tr> <td> *</td> <td> 90 %</td> <td> 99 %</td> </tr> </table> </div> </text> <identifier> <system value="http://goodcare.org/observation/id"/> <value value="o1223435-10"/> </identifier> <partOf> <reference value="Procedure/ob"/> </partOf> <status value="final"/> <category> <coding> <system value="http://terminology.hl7.org/CodeSystem/observation-category"/> <code value="vital-signs"/> <display value="Vital Signs"/> </coding> <text value="Vital Signs"/> </category> <code> <coding> <system value="http://loinc.org"/> <!-- LOINC --> <code value="2708-6"/> <display value="Oxygen saturation in Arterial blood"/> </coding> <!-- Example of a translation to a more specific code to the vitals profile LOINC code --> <coding> <system value="http://loinc.org"/> <!-- LOINC --> <code value="59408-5"/> <display value="Oxygen saturation in Arterial blood by Pulse oximetry"/> </coding> <!-- Example of a translation to a more specific code to the vitals profile LOINC code --> <coding> <system value="urn:iso:std:iso:11073:10101"/> <!-- mdc --> <code value="150456"/> <display value="MDC_PULS_OXIM_SAT_O2"/> </coding> </code> <subject> <reference value="Patient/example"/> </subject> <effectiveDateTime value="2014-12-05T09:30:10+01:00"/> <valueQuantity> <value value="95"/> <unit value="%"/> <system value="http://unitsofmeasure.org"/> <code value="%"/> </valueQuantity> <interpretation> <coding> <system value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/> <code value="N"/> <display value="Normal"/> </coding> <text value="Normal (applies to non-numeric results)"/> </interpretation> <device> <reference value="DeviceMetric/example"/> </device> <referenceRange> <low> <value value="90"/> <unit value="%"/> <system value="http://unitsofmeasure.org"/> <code value="%"/> </low> <high> <value value="99"/> <unit value="%"/> <system value="http://unitsofmeasure.org"/> <code value="%"/> </high> </referenceRange> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.