This page is part of the FHIR Specification (v4.6.0: R5 Draft Ballot). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3
| Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw Turtle (+ also see Turtle/RDF Format Specification)
Oxygen Saturation by Pulse Oximetry Example (DeviceMetricObservation profile)
@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/rdf#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir/Observation/satO2> a fhir:Observation;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "satO2"];
fhir:Resource.meta [
fhir:Meta.profile [
fhir:value "http://hl7.org/fhir/StructureDefinition/vitalsigns";
fhir:index 0;
fhir:link <http://hl7.org/fhir/StructureDefinition/vitalsigns>
]
];
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ];
fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>identifier</b>: id: o1223435-10</p><p><b>partOf</b>: <a>Generated Summary: status: completed; <span>OB</span>; <span>Vaginal delivery</span>; occurrence: 2012-06-02; <span>delivery of healthy male infant</span></a></p><p/><p><b>category</b>: <span>Vital Signs</span></p><p><b>code</b>: <span>Oxygen saturation in Arterial blood</span></p><p><b>subject</b>: <a>Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410 5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a></p><p><b>effective</b>: 5 Dec. 2014, 7:30:10 pm</p><p><b>value</b>: 95 %</p><p><b>interpretation</b>: <span>Normal (applies to non-numeric results)</span></p><p><b>device</b>: <a>Generated Summary: id: 345675; <span>MDC_PULS_OXIM_SAT_O2</span>; <span>MDC_DIM_PERCENT</span>; operationalStatus: on; color: blue; category: measurement; Do Once per 1 seconds</a></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>90 %</td><td>99 %</td></tr></table></div>"
];
fhir:Observation.identifier [
fhir:index 0;
fhir:Identifier.system [ fhir:value "http://goodcare.org/observation/id" ];
fhir:Identifier.value [ fhir:value "o1223435-10" ]
];
fhir:Observation.partOf [
fhir:index 0;
fhir:link <http://hl7.org/fhir/Procedure/ob>;
fhir:Reference.reference [ fhir:value "Procedure/ob" ]
];
fhir:Observation.status [ fhir:value "final"];
fhir:Observation.category [
fhir:index 0;
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/observation-category" ];
fhir:Coding.code [ fhir:value "vital-signs" ];
fhir:Coding.display [ fhir:value "Vital Signs" ]
];
fhir:CodeableConcept.text [ fhir:value "Vital Signs" ]
];
fhir:Observation.code [
fhir:CodeableConcept.coding [
fhir:index 0;
a loinc:2708-6;
fhir:Coding.system [ fhir:value "http://loinc.org" ];
fhir:Coding.code [ fhir:value "2708-6" ];
fhir:Coding.display [ fhir:value "Oxygen saturation in Arterial blood" ]
], [
fhir:index 1;
a loinc:59408-5;
fhir:Coding.system [ fhir:value "http://loinc.org" ];
fhir:Coding.code [ fhir:value "59408-5" ];
fhir:Coding.display [ fhir:value "Oxygen saturation in Arterial blood by Pulse oximetry" ]
], [
fhir:index 2;
fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
fhir:Coding.code [ fhir:value "150456" ];
fhir:Coding.display [ fhir:value "MDC_PULS_OXIM_SAT_O2" ]
]
];
fhir:Observation.subject [
fhir:link <http://hl7.org/fhir/Patient/example>;
fhir:Reference.reference [ fhir:value "Patient/example" ]
];
fhir:Observation.effectiveDateTime [ fhir:value "2014-12-05T09:30:10+01:00"^^xsd:dateTime];
fhir:Observation.valueQuantity [
fhir:Quantity.value [ fhir:value "95"^^xsd:decimal ];
fhir:Quantity.unit [ fhir:value "%" ];
fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
fhir:Quantity.code [ fhir:value "%" ]
];
fhir:Observation.interpretation [
fhir:index 0;
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation" ];
fhir:Coding.code [ fhir:value "N" ];
fhir:Coding.display [ fhir:value "Normal" ]
];
fhir:CodeableConcept.text [ fhir:value "Normal (applies to non-numeric results)" ]
];
fhir:Observation.device [
fhir:link <http://hl7.org/fhir/DeviceMetric/example>;
fhir:Reference.reference [ fhir:value "DeviceMetric/example" ]
];
fhir:Observation.referenceRange [
fhir:index 0;
fhir:Observation.referenceRange.low [
fhir:Quantity.value [ fhir:value "90"^^xsd:decimal ];
fhir:Quantity.unit [ fhir:value "%" ];
fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
fhir:Quantity.code [ fhir:value "%" ]
];
fhir:Observation.referenceRange.high [
fhir:Quantity.value [ fhir:value "99"^^xsd:decimal ];
fhir:Quantity.unit [ fhir:value "%" ];
fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
fhir:Quantity.code [ fhir:value "%" ]
]
] .
<http://hl7.org/fhir/Procedure/ob> a fhir:Procedure .
<http://hl7.org/fhir/Patient/example> a fhir:Patient .
<http://hl7.org/fhir/DeviceMetric/example> a fhir:DeviceMetric .
# - ontology header ------------------------------------------------------------
<http://hl7.org/fhir/Observation/satO2.ttl> a owl:Ontology;
owl:imports fhir:fhir.ttl;
owl:versionIRI <http://build.fhir.org/Observation/satO2.ttl> .
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.