This page is part of the FHIR Specification (v4.6.0: R5 Draft Ballot). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
Real-world patient -base excess (id = "f002")
<?xml version="1.0" encoding="UTF-8"?> <Observation xmlns="http://hl7.org/fhir"> <id value="f002"/> <!-- urn:oid:2.16.840.1.113883.4.642.1.7 --><!-- 2.16.840.1.113883.4.642.1.118 --><text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> identifier</b> : id: 6324 (OFFICIAL)</p> <p/> <p> <b> code</b> : <span> Base excess in Blood by calculation</span> </p> <p> <b> subject</b> : <a> P. van de Heuvel. Generated Summary: id: 738472983 (USUAL), id: ?ngen-9? (USUAL); active; Pieter van de Heuvel ; Phone: 0648352638, p.heuvel@gmail.com; gender: male; birthDate: 1944-11-17; <span> Getrouwd</span> ; multipleBirth</a> </p> <p> <b> effective</b> : 2 Apr. 2013, 8:30:10 pm --> 5 Apr. 2013, 8:30:10 pm</p> <p> <b> issued</b> : 4 Apr. 2013, 1:30:10 am</p> <p> <b> performer</b> : <a> A. Langeveld. Generated Summary: id: 118265112 (OFFICIAL), id: 191REW8WE916 (USUAL); Langeveld Anne (OFFICIAL); Phone: 0205563847, a.langeveld@bmc.nl, Fax: 0205668916; gender: female; birthDate: 1959-03-11; <span> France</span> </a> </p> <p> <b> value</b> : 12.6 mmol/l</p> <p> <b> interpretation</b> : <span> High</span> </p> <h3> ReferenceRanges</h3> <table> <tr> <td> -</td> <td> <b> Low</b> </td> <td> <b> High</b> </td> </tr> <tr> <td> *</td> <td> 7.1 mmol/l</td> <td> 11.2 mmol/l</td> </tr> </table> </div> </text> <identifier> <use value="official"/> <system value="http://www.bmc.nl/zorgportal/identifiers/observations"/> <value value="6324"/> </identifier> <status value="final"/> <code> <coding> <system value="http://loinc.org"/> <code value="11555-0"/> <display value="Base excess in Blood by calculation"/> </coding> </code> <subject> <reference value="Patient/f001"/> <display value="P. van de Heuvel"/> </subject> <effectivePeriod> <start value="2013-04-02T10:30:10+01:00"/> <end value="2013-04-05T10:30:10+01:00"/> </effectivePeriod> <issued value="2013-04-03T15:30:10+01:00"/> <performer> <reference value="Practitioner/f005"/> <display value="A. Langeveld"/> </performer> <valueQuantity> <value value="12.6"/> <unit value="mmol/l"/> <system value="http://unitsofmeasure.org"/> <code value="mmol/L"/> </valueQuantity> <interpretation> <coding> <system value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/> <code value="H"/> <display value="High"/> </coding> </interpretation> <referenceRange> <low> <value value="7.1"/> <unit value="mmol/l"/> <system value="http://unitsofmeasure.org"/> <code value="mmol/L"/> </low> <high> <value value="11.2"/> <unit value="mmol/l"/> <system value="http://unitsofmeasure.org"/> <code value="mmol/L"/> </high> </referenceRange> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.