This page is part of the FHIR Specification (v4.6.0: R5 Draft Ballot). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3 R2
| Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Blood Pressure Measurement cancelled
{
"resourceType": "Observation",
"id": "blood-pressure-cancel",
"meta": {
"profile": [
"http://hl7.org/fhir/StructureDefinition/vitalsigns"
]
},
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>identifier</b>: id: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281</p><p><b>status</b>: cancelled</p><p><b>category</b>: <span>Vital Signs</span></p><p><b>code</b>: <span>Blood pressure systolic & diastolic</span></p><p><b>subject</b>: <a>Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410 5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a></p><p><b>effective</b>: 2012-09-17</p><p><b>performer</b>: <a>Generated Summary: id: 23; active; Adam Careful </a></p><p><b>interpretation</b>: <span>Below low normal</span></p><p><b>note</b>: In this example, the blood pressure measurements are not available due to cancellation of the order. Data absent reason is present for each component</p><p><b>bodySite</b>: <span>Right arm</span></p><blockquote><p><b>component</b></p><p><b>code</b>: <span>Systolic blood pressure</span></p><p><b>dataAbsentReason</b>: <span>Not Asked</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span>Diastolic blood pressure</span></p><p><b>dataAbsentReason</b>: <span>Not Asked</span></p></blockquote></div>"
},
"identifier": [
{
"system": "urn:ietf:rfc:3986",
"value": "urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281"
}
],
"status": "cancelled",
"category": [
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/observation-category",
"code": "vital-signs",
"display": "Vital Signs"
}
]
}
],
"code": {
"coding": [
{
"system": "http://loinc.org",
"code": "85354-9",
"display": "Blood pressure panel with all children optional"
}
],
"text": "Blood pressure systolic & diastolic"
},
"subject": {
"reference": "Patient/example"
},
"effectiveDateTime": "2012-09-17",
"performer": [
{
"reference": "Practitioner/example"
}
],
"interpretation": [
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
"code": "L",
"display": "low"
}
],
"text": "Below low normal"
}
],
"note": [
{
"text": "In this example, the blood pressure measurements are not available due to cancellation of the order. Data absent reason is present for each component"
}
],
"bodySite": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "368209003",
"display": "Right arm"
}
]
},
"component": [
{
"code": {
"coding": [
{
"system": "http://loinc.org",
"code": "8480-6",
"display": "Systolic blood pressure"
},
{
"system": "http://snomed.info/sct",
"code": "271649006",
"display": "Systolic blood pressure"
},
{
"system": "http://acme.org/devices/clinical-codes",
"code": "bp-s",
"display": "Systolic Blood pressure"
}
]
},
"dataAbsentReason": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/data-absent-reason",
"code": "not-asked",
"display": "Not Asked"
}
]
}
},
{
"code": {
"coding": [
{
"system": "http://loinc.org",
"code": "8462-4",
"display": "Diastolic blood pressure"
}
]
},
"dataAbsentReason": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/data-absent-reason",
"code": "not-asked",
"display": "Not Asked"
}
]
}
}
]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.