This page is part of the FHIR Specification (v4.6.0: R5 Draft Ballot). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
Intravenous Admixture - Potassium Chloride in D5W (id = "medadmin0302")
<?xml version="1.0" encoding="UTF-8"?> <MedicationAdministration xmlns="http://hl7.org/fhir"> <id value="medadmin0302"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> partOf</b> : <a> Generated Summary: status: completed; <span> Diagnostic procedure</span> ; <span> Biopsy of suspected melanoma L) arm</span> ; occurrence: 2014-02-03; recorded: 2014-02-03; <span> Left forearm</span> ; <span> Ineffective airway clearance</span> ; <span> Review in clinic</span> ; Standard Biopsy</a> </p> <p> <b> status</b> : completed</p> <p> <b> category</b> : <span> Inpatient</span> </p> <h3> Medications</h3> <table> <tr> <td> -</td> </tr> <tr> <td> *</td> </tr> </table> <p> <b> subject</b> : <a> Donald Duck. Generated Summary: Medical record number: 654321 (USUAL); active; Duck Donald (OFFICIAL); gender: male</a> </p> <p> <b> encounter</b> : <a> encounter who leads to this prescription. Generated Summary: id: v1451 (OFFICIAL); status: completed; <span> ambulatory</span> ; <span> Patient-initiated encounter</span> ; <span> Non-urgent cardiological admission</span> </a> </p> <p> <b> occurence</b> : 15 Jan. 2015, 2:30:00 pm --> 16 Jan. 2015, 12:30:00 am</p> <h3> Performers</h3> <table> <tr> <td> -</td> <td> <b> Actor</b> </td> </tr> <tr> <td> *</td> <td> <a> Patrick Pump. Generated Summary: id: 874635264 (OFFICIAL), id: 567IUI51C154 (USUAL); Simone Heps (OFFICIAL); Phone: 020556936, S.M.Heps@bmc.nl, Fax: 0205669283; gender: female; birthDate: 1971-11-07</a> </td> </tr> </table> <h3> Reasons</h3> <table> <tr> <td> -</td> </tr> <tr> <td> *</td> </tr> </table> <p> <b> request</b> : <a> Generated Summary: id: 12345689 (OFFICIAL); status: completed; intent: order; authoredOn: 2015-01-15</a> </p> <h3> Dosages</h3> <table> <tr> <td> -</td> <td> <b> Text</b> </td> <td> <b> Site</b> </td> <td> <b> Route</b> </td> <td> <b> Method</b> </td> <td> <b> Dose</b> </td> <td> <b> Rate[x]</b> </td> </tr> <tr> <td> *</td> <td> KCl 20 mEq in 1 L 0.9%NS IV at 100 ml/hr</td> <td> <span> Structure of ligament of left superior vena cava</span> </td> <td> <span> Intravenous route (qualifier value)</span> </td> <td> <span> Continuous infusion</span> </td> <td> 20 meq</td> <td> 100 mL/1 h</td> </tr> </table> </div> </text> <contained> <Medication> <id value="med0317"/> <doseForm> <coding> <system value="http://snomed.info/sct"/> <code value="385219001"/> <display value="Injection Solution (qualifier value)"/> </coding> <text value="Injection Solution (qualifier value)"/> </doseForm> <ingredient> <item> <concept> <coding> <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> <code value="204520"/> <display value="Potassium Chloride"/> </coding> </concept> </item> <strengthRatio> <numerator> <value value="2"/> <system value="http://unitsofmeasure.org"/> <code value="meq"/> </numerator> <denominator> <value value="1"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </strengthRatio> </ingredient> <ingredient> <item> <concept> <coding> <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> <code value="313002"/> <display value="Sodium Chloride 0.9% injectable solution"/> </coding> </concept> </item> <strengthRatio> <numerator> <value value="0.9"/> <system value="http://unitsofmeasure.org"/> <code value="g"/> </numerator> <denominator> <value value="100"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </strengthRatio> </ingredient> </Medication> </contained> <partOf> <reference value="Procedure/biopsy"/> </partOf> <status value="completed"/> <category> <coding> <system value="http://terminology.hl7.org/CodeSystem/medication-admin-category"/> <code value="inpatient"/> <display value="Inpatient"/> </coding> </category> <medication> <reference> <reference value="#med0317"/> </reference> </medication> <subject> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </subject> <encounter> <reference value="Encounter/f001"/> <display value="encounter who leads to this prescription"/> </encounter> <occurencePeriod> <start value="2015-01-15T04:30:00+01:00"/> <end value="2015-01-15T14:30:00+01:00"/> </occurencePeriod> <performer> <actor> <reference value="Practitioner/f007"/> <display value="Patrick Pump"/> </actor> </performer> <reason> <concept> <coding> <system value="http://terminology.hl7.org/CodeSystem/reason-medication-given"/> <code value="b"/> <display value="Given as Ordered"/> </coding> </concept> </reason> <request> <reference value="MedicationRequest/medrx0322"/> </request> <dosage> <text value="KCl 20 mEq in 1 L 0.9%NS IV at 100 ml/hr"/> <site> <coding> <system value="http://snomed.info/sct"/> <code value="6073002"/> <display value="Structure of ligament of left superior vena cava"/> </coding> </site> <route> <coding> <system value="http://snomed.info/sct"/> <code value="47625008"/> <display value="Intravenous route (qualifier value)"/> </coding> </route> <method> <text value="Continuous infusion"/> </method> <dose> <value value="20"/> <unit value="meq"/> <system value="http://unitsofmeasure.org"/> <code value="meq"/> </dose> <rateRatio> <numerator> <value value="100"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </numerator> <denominator> <value value="1"/> <system value="http://unitsofmeasure.org"/> <code value="h"/> </denominator> </rateRatio> </dosage> </MedicationAdministration>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.