This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Vocabulary Work Group | Maturity Level: N/A | Standards Status: Informative |
Raw XML (canonical form + also see XML Format Specification)
Definition for Value SetParticipant type
<?xml version="1.0" encoding="UTF-8"?> <ValueSet xmlns="http://hl7.org/fhir"> <id value="encounter-participant-type"/> <meta> <lastUpdated value="2020-08-20T17:41:31.970+10:00"/> <profile value="http://hl7.org/fhir/StructureDefinition/shareablevalueset"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p> This value set includes codes based on the following rules:</p> <ul> <li> Include codes from <a href="http://terminology.hl7.org/1.0.0/CodeSystem-v3-ParticipationType.html"> <code> http://terminology.hl7.org/CodeSystem/v3-ParticipationType</code> </a> where concept is-a <a href="http://terminology.hl7.org/1.0.0/CodeSystem-v3-ParticipationType.html#v3-ParticipationType-_Particip ationAncillary">_ParticipationAncillary</a> </li> <li> Include these codes as defined in <a href="http://terminology.hl7.org/1.0.0/CodeSystem-v3-ParticipationType.html"> <code> http://terminology.hl7.org/CodeSystem/v3-ParticipationType</code> </a> <table class="none"> <tr> <td style="white-space:nowrap"> <b> Code</b> </td> <td> <b> Display</b> </td> </tr> <tr> <td> <a href="http://terminology.hl7.org/1.0.0/CodeSystem-v3-ParticipationType.html#v3-ParticipationType-SPRF">SPRF</a> </td> <td> secondary performer</td> <td> A person assisting in an act through his substantial presence and involvement This includes: assistants, technicians, associates, or whatever the job titles may be.</td> </tr> <tr> <td> <a href="http://terminology.hl7.org/1.0.0/CodeSystem-v3-ParticipationType.html#v3-ParticipationType-PPRF">PPRF</a> </td> <td> primary performer</td> <td> The principal or primary performer of the act.</td> </tr> <tr> <td> <a href="http://terminology.hl7.org/1.0.0/CodeSystem-v3-ParticipationType.html#v3-ParticipationType-PART">PART</a> </td> <td> Participation</td> <td> Indicates that the target of the participation is involved in some manner in the act, but does not qualify how.</td> </tr> </table> </li> <li> Include all codes defined in <a href="http://terminology.hl7.org/1.0.0/CodeSystem-participant-type.html"> <code> http://terminology.hl7.org/CodeSystem/participant-type</code> </a> </li> </ul> <p> This value set excludes codes based on the following rules:</p> <ul> <li> Exclude these codes as defined in <a href="http://terminology.hl7.org/1.0.0/CodeSystem-v3-ParticipationType.html"> <code> http://terminology.hl7.org/CodeSystem/v3-ParticipationType</code> </a> <table class="none"> <tr> <td style="white-space:nowrap"> <b> Code</b> </td> <td> <b> Display</b> </td> </tr> <tr> <td> <a href="http://terminology.hl7.org/1.0.0/CodeSystem-v3-ParticipationType.html#v3-ParticipationType-_Particip ationAncillary">_ParticipationAncillary</a> </td> <td> ParticipationAncillary</td> <td> Participations related, but not primary to an act. The Referring, Admitting, and Discharging practitioners must be the same person as those authoring the ControlAct event for their respective trigger events.</td> </tr> </table> </li> </ul> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"> <valueCode value="pa"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status"> <valueCode value="trial-use"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm"> <valueInteger value="3"/> </extension> <url value="http://hl7.org/fhir/ValueSet/encounter-participant-type"/> <identifier> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.840.1.113883.4.642.3.250"/> </identifier> <version value="4.5.0"/> <name value="ParticipantType"/> <title value="Participant type"/> <status value="draft"/> <experimental value="false"/> <date value="2020-08-20T17:41:31+10:00"/> <publisher value="FHIR Project team"/> <contact> <telecom> <system value="url"/> <value value="http://hl7.org/fhir"/> </telecom> </contact> <description value="This value set defines a set of codes that can be used to indicate how an individual participates in an encounter."/> <compose> <include> <system value="http://terminology.hl7.org/CodeSystem/v3-ParticipationType"/> <filter> <property value="concept"/> <op value="is-a"/> <value value="_ParticipationAncillary"/> </filter> </include> <include> <system value="http://terminology.hl7.org/CodeSystem/v3-ParticipationType"/> <concept> <code value="SPRF"/> </concept> <concept> <code value="PPRF"/> </concept> <concept> <code value="PART"/> </concept> </include> <include> <system value="http://terminology.hl7.org/CodeSystem/participant-type"/> </include> <exclude> <system value="http://terminology.hl7.org/CodeSystem/v3-ParticipationType"/> <concept> <code value="_ParticipationAncillary"/> </concept> </exclude> </compose> </ValueSet>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.