Release 5 Preview #3

This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

4.4.1.113 Value Set http://hl7.org/fhir/ValueSet/audit-event-type

Security Work Group Maturity Level: 3Trial Use Use Context: Any

This is a value set defined by the FHIR project.

Summary

Defining URL:http://hl7.org/fhir/ValueSet/audit-event-type
Version:4.5.0
Name:AuditEventID
Title:Audit Event ID
Definition:

Event Types for Audit Events - defined by DICOM with some FHIR specific additions.

Committee:Security Work Group
OID:2.16.840.1.113883.4.642.3.462 (for OID based terminology systems)
Copyright:

These codes are excerpted from Digital Imaging and Communications in Medicine (DICOM) Standard, Part 16: Content Mapping Resource, Copyright © 2011 by the National Electrical Manufacturers Association. Additional codes added by HL7 FHIR use-case analysis

Source ResourceXML / JSON

This value set is used in the following places:


This value set includes codes based on the following rules:

 

This expansion generated 20 Aug 2020


This value set contains 16 concepts

Expansion based on:

CodeSystemDisplayDefinition
110100http://dicom.nema.org/resources/ontology/DCMApplication ActivityAudit event: Application Activity has taken place
110101http://dicom.nema.org/resources/ontology/DCMAudit Log UsedAudit event: Audit Log has been used
110102http://dicom.nema.org/resources/ontology/DCMBegin Transferring DICOM InstancesAudit event: Storage of DICOM Instances has begun
110103http://dicom.nema.org/resources/ontology/DCMDICOM Instances AccessedAudit event: DICOM Instances have been created, read, updated, or deleted
110104http://dicom.nema.org/resources/ontology/DCMDICOM Instances TransferredAudit event: Storage of DICOM Instances has been completed
110105http://dicom.nema.org/resources/ontology/DCMDICOM Study DeletedAudit event: Entire Study has been deleted
110106http://dicom.nema.org/resources/ontology/DCMExportAudit event: Data has been exported out of the system
110107http://dicom.nema.org/resources/ontology/DCMImportAudit event: Data has been imported into the system
110108http://dicom.nema.org/resources/ontology/DCMNetwork EntryAudit event: System has joined or left network
110109http://dicom.nema.org/resources/ontology/DCMOrder RecordAudit event: Order has been created, read, updated or deleted
110110http://dicom.nema.org/resources/ontology/DCMPatient RecordAudit event: Patient Record has been created, read, updated, or deleted
110111http://dicom.nema.org/resources/ontology/DCMProcedure RecordAudit event: Procedure Record has been created, read, updated, or deleted
110112http://dicom.nema.org/resources/ontology/DCMQueryAudit event: Query has been made
110113http://dicom.nema.org/resources/ontology/DCMSecurity AlertAudit event: Security Alert has been raised
110114http://dicom.nema.org/resources/ontology/DCMUser AuthenticationAudit event: User Authentication has been attempted
rest http://terminology.hl7.org/CodeSystem/audit-event-typeRESTful OperationAudit Event: Execution of a RESTful operation as defined by FHIR.

 

See the full registry of value sets defined as part of FHIR.


Explanation of the columns that may appear on this page:

LvlA few code lists that FHIR defines are hierarchical - each code is assigned a level. For value sets, levels are mostly used to organize codes for user convenience, but may follow code system hierarchy - see Code System for further information
SourceThe source of the definition of the code (when the value set draws in codes defined elsewhere)
CodeThe code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
DisplayThe display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
DefinitionAn explanation of the meaning of the concept
CommentsAdditional notes about how to use the code