Release 5 Preview #3

This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Task-example-fm-reprocess.json

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Not linked to any defined compartments

Raw JSON (canonical form + also see JSON Format Specification)

Example of the cancellation of a preauthorization

{
  "resourceType": "Task",
  "id": "fm-example4",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n\t\t\t<p>\n\t\t\t\t<b> Generated Narrative with Details</b>\n\t\t\t</p>\n\t\t</div>"
  },
  "identifier": [
    {
      "use": "official",
      "system": "http:/happyvalley.com/task",
      "value": "20181012-006"
    }
  ],
  "status": "requested",
  "intent": "order",
  "priority": "stat",
  "code": {
    "coding": [
      {
        "system": "http://terminology.hl7.org/CodeSystem/financialtaskcode",
        "code": "reprocess"
      }
    ]
  },
  "focus": {
    "identifier": {
      "system": "http://happyvalley.com/claim",
      "value": "1501"
    }
  },
  "authoredOn": "2018-10-04T08:25:05+10:00",
  "lastModified": "2018-10-04T08:25:05+10:00",
  "requester": {
    "reference": "Organization/example",
    "display": "Happy Valley Clinic"
  },
  "owner": {
    "identifier": {
      "system": "http://nationalinsurers.com/identifiers",
      "value": "12345"
    }
  },
  "input": [
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/financialtaskinputtype",
            "code": "origresponse"
          }
        ]
      },
      "valueReference": {
        "identifier": {
          "system": "http://nationalinsurers.com/claimresponse",
          "value": "CR201810040001234"
        }
      }
    },
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/financialtaskinputtype",
            "code": "reference"
          }
        ]
      },
      "valueString": "BR12345"
    },
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/financialtaskinputtype",
            "code": "item"
          }
        ]
      },
      "valuePositiveInt": 2
    },
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/financialtaskinputtype",
            "code": "item"
          }
        ]
      },
      "valuePositiveInt": 3
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.