Release 5 Preview #3

This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Servicerequest-example-ventilation.xml

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Order for mechanical ventilation with order details (id = "vent")

<?xml version="1.0" encoding="UTF-8"?>

<ServiceRequest xmlns="http://hl7.org/fhir">
  <id value="vent"/> 
  <!--    Example of a ventilation order with provider instructions    -->
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> id</b> : vent</p> <p> <b> status</b> : completed</p> <p> <b> intent</b> : order</p> <p> <b> code</b> : <span> Mechanical Ventilation</span> </p> <p> <b> orderDetail</b> : <span> IPPB</span> , <span>  Initial Settings : Sens: -1 cm H20 Pressure 15 cm H2O moderate flow:  Monitor VS every
           15 minutes x 4 at the start of mechanical ventilation, then routine for unit OR every
           5 hr</span> </p> <p> <b> subject</b> : <a> Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James
           Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555
           6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate:
           1974-12-25; </a> </p> <p> <b> authoredOn</b> : 2018-02-20</p> <p> <b> requester</b> : <a> Dr. Beverly Crusher. Generated Summary: id: 3ad0687e-f477-468c-afd5-fcc2bf897809; </a> </p> <p> <b> performer</b> : <a> Dr Cecil Surgeon. Generated Summary: id: example; id: 23; active; Adam Careful </a> </p> <p> <b> reason</b> : </p> </div> </text> <status value="completed"/> 
  <intent value="order"/> 
  <code> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="40617009"/> 
      <display value="Artificial respiration (procedure)"/> 
    </coding> 
    <text value="Mechanical Ventilation"/> 
  </code> 
  <orderDetail> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="243144002"/> 
      <display value="Patient triggered inspiratory assistance (procedure)"/> 
    </coding> 
    <text value="IPPB"/> 
  </orderDetail> 
  <orderDetail> 
    <text value=" Initial Settings : Sens: -1 cm H20 Pressure 15 cm H2O moderate flow:  Monitor VS every
     15 minutes x 4 at the start of mechanical ventilation, then routine for unit OR every
     5 hr"/> 
  </orderDetail> 
  <subject> 
    <reference value="Patient/example"/> 
  </subject> 
  <authoredOn value="2018-02-20"/> 
  <requester> 
    <reference value="Practitioner/3ad0687e-f477-468c-afd5-fcc2bf897809"/> 
    <display value="Dr. Beverly Crusher"/> 
  </requester> 
  <performer> 
    <reference value="Practitioner/example"/> 
    <display value="Dr Cecil Surgeon"/> 
  </performer> 
  <reason> 
    <concept> 
      <text value="chronic obstructive lung disease (COLD)"/> 
    </concept> 
  </reason> 
</ServiceRequest> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.