Release 5 Preview #3

This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Servicerequest-example-lipid.json

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw JSON (canonical form + also see JSON Format Specification)

Lipid Panel Order

{
  "resourceType": "ServiceRequest",
  "id": "lipid",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>id</b>: lipid</p><p><b>identifier</b>: Placer: 2345234234234</p><p><b>status</b>: active</p><p><b>intent</b>: original-order</p><p><b>code</b>: <span>Lipid Panel</span></p><p><b>subject</b>: <a>Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a></p><p><b>encounter</b>: <a>Generated Summary: id: example; status: in-progress; <span>inpatient encounter</span></a></p><p><b>occurrence</b>: 03/05/2013 9:16:00 AM</p><p><b>requester</b>: <a>Generated Summary: id: example; id: 23; active; Adam Careful </a></p><p><b>performer</b>: <a>Generated Summary: id: f202; UZI-nummer: 12345678902 (OFFICIAL), BIG-nummer: 12345678902 (OFFICIAL); active; Luigi Maas(OFFICIAL); ph: +31715269111(WORK); gender: male; birthDate: 1960-06-12</a></p><p><b>reason</b>: </p><p><b>supportingInfo</b>: <a> </a></p><blockquote><p><b>id</b>: fasting</p><p/><p><b>code</b>: <span>Fasting status - Reported</span></p><p><b>subject</b>: <a>Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a></p><p><b>value</b>: <span>Yes</span></p></blockquote><p><b>specimen</b>: <a> </a></p><blockquote><p><b>id</b>: serum</p><p><b>identifier</b>: id: 20150107-0012</p><p><b>type</b>: <span>Serum sample</span></p><p><b>subject</b>: <a>Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a></p><h3>Collections</h3><table><tr><td>-</td><td><b>Collected[x]</b></td></tr><tr><td>*</td><td>16/08/2015 4:40:17 PM</td></tr></table></blockquote><p><b>note</b>: patient is afraid of needles</p></div>"
  },
  "contained": [
    {
      "resourceType": "Observation",
      "id": "fasting",
      "status": "final",
      "code": {
        "coding": [
          {
            "system": "http://loinc.org",
            "code": "49541-6",
            "display": "Fasting status - Reported"
          }
        ]
      },
      "subject": {
        "reference": "Patient/example"
      },
      "valueCodeableConcept": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/v2-0136",
            "code": "Y",
            "display": "Yes"
          }
        ]
      }
    },
    {
      "resourceType": "Specimen",
      "id": "serum",
      "identifier": [
        {
          "system": "http://acme.org/specimens",
          "value": "20150107-0012"
        }
      ],
      "type": {
        "coding": [
          {
            "system": "http://snomed.info/sct",
            "code": "119364003",
            "display": "Serum sample"
          }
        ]
      },
      "subject": {
        "reference": "Patient/example"
      },
      "collection": {
        "collectedDateTime": "2015-08-16T06:40:17Z"
      }
    }
  ],
  "identifier": [
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/v2-0203",
            "code": "PLAC"
          }
        ],
        "text": "Placer"
      },
      "system": "urn:oid:1.3.4.5.6.7",
      "value": "2345234234234"
    }
  ],
  "status": "active",
  "intent": "original-order",
  "code": {
    "coding": [
      {
        "system": "http://acme.org/tests",
        "code": "LIPID"
      }
    ],
    "text": "Lipid Panel"
  },
  "subject": {
    "reference": "Patient/example"
  },
  "encounter": {
    "reference": "Encounter/example"
  },
  "occurrenceDateTime": "2013-05-02T16:16:00-07:00",
  "requester": {
    "reference": "Practitioner/example"
  },
  "performer": [
    {
      "reference": "Practitioner/f202"
    }
  ],
  "reason": [
    {
      "concept": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/sid/icd-9",
            "code": "V173",
            "display": "Fam hx-ischem heart dis"
          }
        ]
      }
    }
  ],
  "supportingInfo": [
    {
      "reference": "#fasting",
      "display": "Fasting status"
    }
  ],
  "specimen": [
    {
      "reference": "#serum",
      "display": "Serum specimen"
    }
  ],
  "note": [
    {
      "text": "patient is afraid of needles"
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.