This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Patient Care Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Example of a device manipulation
{ "resourceType": "Procedure", "id": "example-implant", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>id</b>: example-implant</p><p><b>status</b>: completed</p><p><b>code</b>: <span>Implant Pacemaker</span></p><p><b>subject</b>: <a>Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a></p><p><b>occurrence</b>: 2015-04-05</p><h3>Performers</h3><table><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a>Dr Cecil Surgeon. Generated Summary: id: example; id: 23; active; Adam Careful </a></td></tr></table><p><b>reason</b>: </p><p><b>followUp</b>: <span>ROS 5 days - 2013-04-10</span></p><p><b>note</b>: Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p><h3>FocalDevices</h3><table><tr><td>-</td><td><b>Action</b></td><td><b>Manipulated</b></td></tr><tr><td>*</td><td><span>Implanted</span></td><td><a> </a><blockquote><p><b>id</b>: example-pacemaker</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>lotNumber</b>: 1234-5678</p><p><b>type</b>: <span>Cardiac pacemaker implant</span></p><p><b>patient</b>: <a>Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a></p></blockquote></td></tr></table></div>" }, "contained": [ { "resourceType": "Device", "id": "example-pacemaker", "manufacturer": "Acme Devices, Inc", "lotNumber": "1234-5678", "type": [ { "coding": [ { "system": "http://snomed.info/sct", "code": "14106009", "display": "Cardiac pacemaker implant" } ] } ], "patient": { "reference": "Patient/example" } } ], "status": "completed", "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "25267002", "display": "Insertion of intracardiac pacemaker (procedure)" } ], "text": "Implant Pacemaker" }, "subject": { "reference": "Patient/example" }, "occurrenceDateTime": "2015-04-05", "performer": [ { "actor": { "reference": "Practitioner/example", "display": "Dr Cecil Surgeon" } } ], "reason": [ { "concept": { "text": "Bradycardia" } } ], "followUp": [ { "text": "ROS 5 days - 2013-04-10" } ], "note": [ { "text": "Routine Appendectomy. Appendix was inflamed and in retro-caecal position" } ], "focalDevice": [ { "action": { "coding": [ { "system": "http://hl7.org/fhir/device-action", "code": "implanted" } ] }, "manipulated": { "reference": "#example-pacemaker" } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.