Release 5 Preview #3

This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Procedure-example-f002-lung.xml

Patient Care Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Real-world procedure example (id = "f002")

<?xml version="1.0" encoding="UTF-8"?>

<Procedure xmlns="http://hl7.org/fhir">
  <id value="f002"/> 
    <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> id</b> : f002</p> <p> <b> status</b> : completed</p> <p> <b> code</b> : <span> Partial lobectomy of lung</span> </p> <p> <b> subject</b> : <a> P. van de Heuvel. Generated Summary: id: f001; id: 738472983 (USUAL), id: ?ngen-9? (USUAL);
           active; Pieter van de Heuvel ; ph: 0648352638(MOBILE), p.heuvel@gmail.com(HOME); gender:
           male; birthDate: 1944-11-17; <span> Getrouwd</span> ; multipleBirth</a> </p> <p> <b> encounter</b> : <a> Generated Summary: id: f002; id: v3251 (OFFICIAL); status: completed; <span> ambulatory</span> ; <span> Patient-initiated encounter</span> ; <span> Urgent</span> ; 140 min; <span> Partial lobectomy of lung</span> </a> </p> <p> <b> occurrence</b> : 08/03/2013 7:00:10 PM --&gt; 08/03/2013 7:30:10 PM</p> <h3> Performers</h3> <table> <tr> <td> -</td> <td> <b> Function</b> </td> <td> <b> Actor</b> </td> </tr> <tr> <td> *</td> <td> <span> Care role</span> </td> <td> <a> M.I.M. Versteegh. Generated Summary: id: f003; id: 846100293 (OFFICIAL), id: 243HID3RT938
               (USUAL); Marc Versteegh (OFFICIAL); ph: 0205562431(WORK), m.versteegh@bmc.nl(WORK), fax:
               0205662948(WORK); gender: male; birthDate: 1963-07-01; <span> Dutch</span> </a> </td> </tr> </table> <p> <b> reason</b> : </p> <p> <b> bodySite</b> : <span> Lung structure</span> </p> <p> <b> outcome</b> : <span> improved blood circulation</span> </p> <p> <b> report</b> : <a> Lab results blood test. Generated Summary: id: f001</a> </p> <p> <b> followUp</b> : <span> described in care plan</span> </p> </div> </text> <status value="completed"/> 
    <code> 
        <coding> 
            <system value="http://snomed.info/sct"/> 
            <code value="359615001"/> 
            <display value="Partial lobectomy of lung"/> 
        </coding> 
    </code> 
  <subject> 
        <reference value="Patient/f001"/> 
        <display value="P. van de Heuvel"/> 
    </subject> 
  <encounter> 
        <reference value="Encounter/f002"/> 
    </encounter> 
    <occurrencePeriod> 
        <start value="2013-03-08T09:00:10+01:00"/> 
        <end value="2013-03-08T09:30:10+01:00"/> 
    </occurrencePeriod> 
  <performer> 
        <function> 
            <coding> 
                <system value="urn:oid:2.16.840.1.113883.2.4.15.111"/>  <!--    "AssignedRoleType" coding system    -->
                <code value="01.000"/> 
                <display value="Arts"/> 
            </coding> 
            <text value="Care role"/> 
        </function> 
    <actor> 
            <reference value="Practitioner/f003"/> 
            <display value="M.I.M. Versteegh"/> 
        </actor> 
    </performer> 
  <reason> 
       <concept> 
         <text value="Malignant tumor of lung"/> 
       </concept> 
    </reason> 
    <bodySite> 
        
            <coding> 
                <system value="http://snomed.info/sct"/> 
                <code value="39607008"/> 
                <display value="Lung structure"/> 
            </coding> 
        
    </bodySite> 
    <outcome> 
      <text value="improved blood circulation"/> 
    </outcome> 
    <report> 
        <reference value="DiagnosticReport/f001"/> 
        <display value="Lab results blood test"/> 
    </report> 
    <followUp> 
      <text value="described in care plan"/> 
    </followUp> 
</Procedure> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.