This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Patient Care Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Real-world procedure example
{ "resourceType": "Procedure", "id": "f001", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>id</b>: f001</p><p><b>status</b>: completed</p><p><b>code</b>: <span>Heart valve replacement</span></p><p><b>subject</b>: <a>P. van de Heuvel. Generated Summary: id: f001; id: 738472983 (USUAL), id: ?ngen-9? (USUAL); active; Pieter van de Heuvel ; ph: 0648352638(MOBILE), p.heuvel@gmail.com(HOME); gender: male; birthDate: 1944-11-17; <span>Getrouwd</span>; multipleBirth</a></p><p><b>encounter</b>: <a>Generated Summary: id: f001; id: v1451 (OFFICIAL); status: completed; <span>ambulatory</span>; <span>Patient-initiated encounter</span>; <span>Non-urgent cardiological admission</span>; 140 min; <span>Heart valve replacement</span></a></p><p><b>occurrence</b>: 2011-06-26 --> 2011-06-27</p><h3>Performers</h3><table><tr><td>-</td><td><b>Function</b></td><td><b>Actor</b></td></tr><tr><td>*</td><td><span>Care role</span></td><td><a>P. Voigt. Generated Summary: id: f002; id: 730291637 (OFFICIAL), id: 174BIP3JH438 (USUAL); Pieter Voigt (OFFICIAL); ph: 0205569336(WORK), p.voigt@bmc.nl(WORK), fax: 0205669382(WORK); gender: male; birthDate: 1979-04-29</a></td></tr></table><p><b>reason</b>: </p><p><b>bodySite</b>: <span>Heart valve structure</span></p><p><b>outcome</b>: <span>improved blood circulation</span></p><p><b>report</b>: <a>Lab results blood test. Generated Summary: id: f001</a></p><p><b>followUp</b>: <span>described in care plan</span></p></div>" }, "status": "completed", "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "34068001", "display": "Heart valve replacement" } ] }, "subject": { "reference": "Patient/f001", "display": "P. van de Heuvel" }, "encounter": { "reference": "Encounter/f001" }, "occurrencePeriod": { "start": "2011-06-26", "end": "2011-06-27" }, "performer": [ { "function": { "coding": [ { "system": "urn:oid:2.16.840.1.113883.2.4.15.111", "code": "01.000", "display": "Arts" } ], "text": "Care role" }, "actor": { "reference": "Practitioner/f002", "display": "P. Voigt" } } ], "reason": [ { "concept": { "text": "Heart valve disorder" } } ], "bodySite": [ { "coding": [ { "system": "http://snomed.info/sct", "code": "17401000", "display": "Heart valve structure" } ] } ], "outcome": { "text": "improved blood circulation" }, "report": [ { "reference": "DiagnosticReport/f001", "display": "Lab results blood test" } ], "followUp": [ { "text": "described in care plan" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.