This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile ObservationDefinition.
Generated Narrative
id: example
status: active
category: Laboratory
code: Albumin/Protein.total in Serum or Plasma by Electrophoresis
permittedDataType: Quantity
multipleResultsAllowed: false
method: Total measurement
preferredReportName: Serum albumin/Protein total
- | Unit | DecimalPrecision |
* | % | 0 |
qualifiedInterval
category: reference
range: 50-?
context: Normal Range
qualifiedInterval
category: critical
range: ?-40
context: Normal Range
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.