This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw Turtle (+ also see Turtle/RDF Format Specification)
An example to demonstrate using the bodyPosition and delta extensions
@prefix fhir: <http://hl7.org/fhir/> . @prefix loinc: <http://loinc.org/rdf#> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Observation/map-sitting> a fhir:Observation; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "map-sitting"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>id</b>: map-sitting</p><p/><p><b>category</b>: <span>Laboratory</span></p><p><b>code</b>: <span>Mean blood pressure</span></p><p><b>subject</b>: <a>Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a></p><p><b>encounter</b>: <a>Generated Summary: id: example; status: in-progress; <span>inpatient encounter</span></a></p><p><b>effective</b>: 02/04/2018 7:30:10 PM --> 05/04/2018 7:30:10 PM</p><p><b>issued</b>: 04/04/2018 12:30:10 AM</p><p><b>value</b>: 60 mm Hg</p><p><b>interpretation</b>: <span>Below low normal</span></p></div>" ]; fhir:DomainResource.extension [ fhir:index 0; fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition" ]; fhir:Extension.valueCodeableConcept [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:33586001; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "33586001" ]; fhir:Coding.display [ fhir:value "Sitting position (finding)" ] ] ] ], [ fhir:index 1; fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/observation-delta" ]; fhir:Extension.valueCodeableConcept [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:1250004; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "1250004" ]; fhir:Coding.display [ fhir:value "Decreased (qualifier value)" ] ] ] ]; fhir:Observation.status [ fhir:value "final"]; fhir:Observation.category [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/observation-category" ]; fhir:Coding.code [ fhir:value "laboratory" ]; fhir:Coding.display [ fhir:value "Laboratory" ] ] ]; fhir:Observation.code [ fhir:CodeableConcept.coding [ fhir:index 0; a loinc:8478-0; fhir:Coding.system [ fhir:value "http://loinc.org" ]; fhir:Coding.code [ fhir:value "8478-0" ]; fhir:Coding.display [ fhir:value "Mean blood pressure" ] ] ]; fhir:Observation.subject [ fhir:link <http://hl7.org/fhir/Patient/example>; fhir:Reference.reference [ fhir:value "Patient/example" ] ]; fhir:Observation.encounter [ fhir:link <http://hl7.org/fhir/Encounter/example>; fhir:Reference.reference [ fhir:value "Encounter/example" ] ]; fhir:Observation.effectivePeriod [ fhir:Period.start [ fhir:value "2018-04-02T10:30:10+01:00"^^xsd:dateTime ]; fhir:Period.end [ fhir:value "2018-04-05T10:30:10+01:00"^^xsd:dateTime ] ]; fhir:Observation.issued [ fhir:value "2018-04-03T15:30:10+01:00"^^xsd:dateTime]; fhir:Observation.valueQuantity [ fhir:Quantity.value [ fhir:value "60"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "mm Hg" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mm[Hg]" ] ]; fhir:Observation.interpretation [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/v2-0078" ]; fhir:Coding.code [ fhir:value "L" ]; fhir:Coding.display [ fhir:value "Low" ] ]; fhir:CodeableConcept.text [ fhir:value "Below low normal" ] ] . <http://hl7.org/fhir/Patient/example> a fhir:Patient . <http://hl7.org/fhir/Encounter/example> a fhir:Encounter . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/Observation/map-sitting.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/Observation/map-sitting.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.