This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner |
Raw XML (canonical form + also see XML Format Specification)
Request for an injectable medication - Lorazepam - active - with link to encounter, reasonCode and dosageInstruction (id = "medrx0315")
<?xml version="1.0" encoding="UTF-8"?> <MedicationRequest xmlns="http://hl7.org/fhir"> <id value="medrx0315"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> id</b> : medrx0315</p> <p> <b> identifier</b> : id: 12345689 (OFFICIAL)</p> <p> <b> status</b> : active</p> <p> <b> intent</b> : order</p> <p> <b> medication</b> : </p> <p> <b> subject</b> : <a> Donald Duck. Generated Summary: id: pat1; Medical record number: 654321 (USUAL); active; Duck Donald (OFFICIAL); gender: male; </a> </p> <p> <b> encounter</b> : <a> encounter who leads to this prescription. Generated Summary: id: f001; id: v1451 (OFFICIAL); status: completed; <span> ambulatory</span> ; <span> Patient-initiated encounter</span> ; <span> Non-urgent cardiological admission</span> ; 140 min; <span> Heart valve replacement</span> </a> </p> <p> <b> authoredOn</b> : 2015-01-15</p> <p> <b> requester</b> : <a> Patrick Pump. Generated Summary: id: f007; id: 874635264 (OFFICIAL), id: 567IUI51C154 (USUAL); Simone Heps (OFFICIAL); ph: 020556936(WORK), S.M.Heps@bmc.nl(WORK), fax: 0205669283(WORK); gender: female; birthDate: 1971-11-07</a> </p> <p> <b> reason</b> : </p> <p> <b> dosageInstruction</b> : </p> </div> </text> <contained> <Medication> <id value="med0313"/> <code> <coding> <system value="http://snomed.info/sct"/> <code value="400621001"/> <display value="Lorazepam 2mg/ml injection solution 1ml vial (product)"/> </coding> </code> <doseForm> <coding> <system value="http://snomed.info/sct"/> <code value="385219001"/> <display value="Injection solution (qualifier value)"/> </coding> </doseForm> <ingredient> <item> <concept> <coding> <system value="http://snomed.info/sct"/> <code value="387106007"/> <display value="Lorazepam (substance)"/> </coding> </concept> </item> <strengthRatio> <numerator> <value value="2"/> <system value="http://unitsofmeasure.org"/> <code value="mg"/> </numerator> <denominator> <value value="1"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </strengthRatio> </ingredient> </Medication> </contained> <identifier> <use value="official"/> <system value="http://www.bmc.nl/portal/prescriptions"/> <value value="12345689"/> </identifier> <status value="active"/> <intent value="order"/> <medication> <!-- Linked to a RESOURCE Medication --> <reference> <reference value="#med0313"/> </reference> </medication> <subject> <!-- Linked to the resource patient who needs the medication --> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </subject> <encounter> <!-- Linked to a resource Encounter between patient and practitioner --> <reference value="Encounter/f001"/> <display value="encounter who leads to this prescription"/> </encounter> <authoredOn value="2015-01-15"/> <requester> <reference value="Practitioner/f007"/> <display value="Patrick Pump"/> </requester> <reason> <concept> <coding> <system value="http://snomed.info/sct"/> <code value="84757009"/> <display value="Epilepsy (disorder)"/> </coding> </concept> </reason> <dosageInstruction> <sequence value="1"/> <text value="0.05 - 0.1mg/kg IV over 2-5 minutes every 15 minutes as needed"/> <timing> <repeat> <frequency value="1"/> <period value="15"/> <periodUnit value="min"/> </repeat> </timing> <asNeededBoolean value="true"/> <route> <coding> <system value="http://snomed.info/sct"/> <code value="255560000"/> <display value="Intravenous"/> </coding> </route> <method> <coding> <system value="http://snomed.info/sct"/> <code value="420620005"/> <display value="Push - dosing instruction imperative (qualifier value)"/> </coding> </method> <doseAndRate> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/dose-rate-type"/> <code value="ordered"/> <display value="Ordered"/> </coding> </type> <doseRange> <low> <value value="0.05"/> <unit value="mg/kg"/> <system value="http://unitsofmeasure.org"/> <code value="mg/kg"/> </low> <high> <value value="0.1"/> <unit value="mg/kg"/> <system value="http://unitsofmeasure.org"/> <code value="mg/kg"/> </high> </doseRange> <rateRange> <low> <value value="2"/> <unit value="min"/> <system value="http://unitsofmeasure.org"/> <code value="min"/> </low> <high> <value value="5"/> <unit value="min"/> <system value="http://unitsofmeasure.org"/> <code value="min"/> </high> </rateRange> </doseAndRate> </dosageInstruction> </MedicationRequest>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.