This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Imaging Integration Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Patient |
Raw XML (canonical form + also see XML Format Specification)
Example XR imaging study with full elements (id = "example-xr")
<?xml version="1.0" encoding="UTF-8"?> <ImagingStudy xmlns="http://hl7.org/fhir"> <id value="example-xr"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml">XR Wrist 3+ Views. John Smith (MRN: 09236). Accession: W12342398. Performed: 2017-01-01. 1 series, 2 images.</div> </text> <identifier> <use value="official"/> <system value="urn:dicom:uid"/> <value value="urn:oid:2.16.124.113543.6003.1154777499.30246.19789.3503430046"/> </identifier> <identifier> <use value="usual"/> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/> <code value="ACSN"/> </coding> </type> <value value="W12342398"/> <assigner> <reference value="Organization/dicom-organization"/> </assigner> </identifier> <identifier> <use value="secondary"/> <value value="55551234"/> <assigner> <reference value="Organization/dicom-organization"/> </assigner> </identifier> <status value="available"/> <modality> <system value="http://dicom.nema.org/resources/ontology/DCM"/> <code value="DX"/> </modality> <subject> <reference value="Patient/dicom"/> </subject> <encounter> <reference value="Encounter/example"/> </encounter> <started value="2017-01-01T11:01:20+03:00"/> <basedOn> <reference value="ServiceRequest/example"/> </basedOn> <referrer> <reference value="Practitioner/example"/> </referrer> <interpreter> <reference value="Practitioner/example"/> </interpreter> <endpoint> <reference value="Endpoint/example-wadors"/> </endpoint> <numberOfSeries value="1"/> <numberOfInstances value="2"/> <procedure> <valueReference> <reference value="Procedure/example"/> </valueReference> </procedure> <procedure> <valueCodeableConcept> <coding> <system value="http://www.radlex.org"/> <code value="RPID2589"/> <display value="XR Wrist 3+ Views"/> </coding> <text value="XR Wrist 3+ Views"/> </valueCodeableConcept> </procedure> <reason> <concept> <coding> <system value="http://snomed.info/sct"/> <code value="357009"/> <display value="Closed fracture of trapezoidal bone of wrist"/> </coding> </concept> </reason> <note> <text value="XR Wrist 3+ Views"/> </note> <series> <uid value="2.16.124.113543.6003.1154777499.30246.19789.3503430045.1"/> <number value="3"/> <modality> <system value="http://dicom.nema.org/resources/ontology/DCM"/> <code value="DX"/> </modality> <description value="XR Wrist 3+ Views"/> <numberOfInstances value="2"/> <endpoint> <reference value="Endpoint/example-wadors"/> </endpoint> <bodySite> <!-- Added body site to support duplicate checking example --> <system value="http://snomed.info/sct"/> <code value="T-15460"/> <display value="Wrist Joint"/> </bodySite> <laterality> <system value="http://snomed.info/sct"/> <code value="419161000"/> <display value="Unilateral left"/> </laterality> <started value="2011-01-01T11:01:20+03:00"/> <performer> <function> <coding> <system value="http://terminology.hl7.org/CodeSystem/v3-ParticipationType"/> <code value="PRF"/> </coding> </function> <actor> <reference value="Practitioner/example"/> </actor> </performer> <instance> <uid value="2.16.124.113543.6003.1154777499.30246.19789.3503430045.1.1"/> <sopClass> <system value="urn:ietf:rfc:3986"/> <code value="urn:oid:1.2.840.10008.5.1.4.1.1.2"/> </sopClass> <number value="1"/> <title value="PA VIEW"/> </instance> <instance> <uid value="2.16.124.113543.6003.1154777499.30246.19789.3503430045.1.2"/> <sopClass> <system value="urn:ietf:rfc:3986"/> <code value="urn:oid:1.2.840.10008.5.1.4.1.1.2"/> </sopClass> <number value="2"/> <title value="LL VIEW"/> </instance> </series> </ImagingStudy>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.