This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner |
Raw JSON (canonical form + also see JSON Format Specification)
Left Lens prescription using the parameters element
{ "resourceType": "DeviceRequest", "id": "left-lens", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>id</b>: left-lens</p><p><b>identifier</b>: id: 15013L</p><p><b>groupIdentifier</b>: id: 15013</p><p><b>status</b>: completed</p><p><b>intent</b>: original-order</p><p><b>code</b>: </p><blockquote><p><b>parameter</b></p><p><b>code</b>: <span>sphere, left lens</span></p><p><b>value</b>: -1.00 Diopter</p></blockquote><blockquote><p><b>parameter</b></p><p><b>code</b>: <span>cylinder, left lens</span></p><p><b>value</b>: -0.50 Diopter</p></blockquote><blockquote><p><b>parameter</b></p><p><b>code</b>: <span>axis, left lens</span></p><p><b>value</b>: 180 Degrees</p></blockquote><p><b>subject</b>: <a>Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a></p><p><b>occurrence</b>: 2014-06-15</p><p><b>requester</b>: <a>Generated Summary: id: example; id: 23; active; Adam Careful </a></p></div>" }, "identifier": [ { "system": "http://www.happysight.com/prescription", "value": "15013L" } ], "groupIdentifier": { "system": "http://acme.org", "value": "15013" }, "status": "completed", "intent": "original-order", "code": { "concept": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct", "code": "lens" } ] } }, "parameter": [ { "code": { "coding": [ { "system": "http://loinc.org", "code": "28842-3", "display": "Sphere distance Glasses prescription.lens - left" } ], "text": "sphere, left lens" }, "valueQuantity": { "value": -1.00, "unit": "Diopter", "system": "http://unitsofmeasure.org", "code": "[diop]" } }, { "code": { "coding": [ { "system": "http://loinc.org", "code": "28843-1", "display": "Cylinder base distance Glasses prescription.lens - left" } ], "text": "cylinder, left lens" }, "valueQuantity": { "value": -0.50, "unit": "Diopter", "system": "http://unitsofmeasure.org", "code": "[diop]" } }, { "code": { "coding": [ { "system": "http://loinc.org", "code": "28844-9", "display": " Axis distance Glasses prescription.lens - left" } ], "text": "axis, left lens" }, "valueQuantity": { "value": 180, "unit": "Degrees", "system": "http://unitsofmeasure.org", "code": "deg" } } ], "subject": { "reference": "Patient/example" }, "occurrenceDateTime": "2014-06-15", "requester": { "reference": "Practitioner/example" } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.