Release 5 Preview #3

This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Bodystructure-example-tumor.xml

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

This example demonstrates using the bodystructure resource to identify a specific tumor or lesion that will have multiple observations and/or procedures performed on it over time (id = "tumor")

<?xml version="1.0" encoding="UTF-8"?>

<BodyStructure xmlns="http://hl7.org/fhir">
  <id value="tumor"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> id</b> : tumor</p> <p> <b> identifier</b> : id: 12345</p> <p> <b> morphology</b> : <span> Splenic mass</span> </p> <p> <b> location</b> : <span> Spleen</span> </p> <p> <b> description</b> : 7 cm maximum diameter</p> <p> <b> image</b> : </p> <p> <b> patient</b> : <a> Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James
           Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555
           6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate:
           1974-12-25; </a> </p> </div> </text> <identifier> 
    <system value="http://goodhealth.org/bodystructure/identifiers"/> 
    <value value="12345"/> 
  </identifier> 
  <morphology> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="4147007"/> 
      <display value="Mass (morphologic abnormality)"/> 
    </coding> 
    <text value="Splenic mass"/> 
  </morphology> 
  <location> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="78961009"/> 
      <display value="Splenic structure (body structure)"/> 
    </coding> 
    <text value="Spleen"/> 
  </location> 
  <description value="7 cm maximum diameter"/> 
  <image> 
    <!--      The actual image could be anywhere. This is a WADO example using a ficitious url
         -->
    <contentType value="application/dicom"/> 
    <url value="http://imaging.acme.com/wado/server?requestType=WADO&amp;amp;wado_details"/> 
  </image> 
  <patient> 
    <reference value="Patient/example"/> 
  </patient> 
</BodyStructure> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.