This page is part of the FHIR Specification (v4.5.0: R5 Preview #3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Patient |
Raw XML (canonical form + also see XML Format Specification)
This example demonstrates using the bodystructure resource to identify skin patches or other portions of a person or animal that are a focus of a clinical trial and that are subject to repeated observations and/or procedures over time (id = "skin-patch")
<?xml version="1.0" encoding="UTF-8"?> <BodyStructure xmlns="http://hl7.org/fhir"> <id value="skin-patch"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p> <b> id</b> : skin-patch</p> <p> <b> identifier</b> : id: 12345</p> <p> <b> active</b> : false</p> <p> <b> morphology</b> : <span> Skin patch</span> </p> <p> <b> location</b> : <span> Forearm</span> </p> <p> <b> locationQualifier</b> : <span> Left</span> , <span> Volar</span> </p> <p> <b> description</b> : inner surface (volar) of the left forearm</p> <p> <b> patient</b> : <a> Generated Summary: id: example; Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); -unknown-(HOME), ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a> </p> </div> </text> <identifier> <system value="http://goodhealth.org/bodystructure/identifiers"/> <value value="12345"/> </identifier> <!-- bodystructure marked as no longer active - entered in error --> <active value="false"/> <morphology> <text value="Skin patch"/> </morphology> <location> <coding> <system value="http://snomed.info/sct"/> <code value="14975008"/> <display value="Forearm"/> </coding> <text value="Forearm"/> </location> <locationQualifier> <coding> <system value="http://snomed.info/sct"/> <code value="419161000"/> <display value="Unilateral left"/> </coding> <text value="Left"/> </locationQualifier> <locationQualifier> <coding> <system value="http://snomed.info/sct"/> <code value="263929005"/> <display value="Volar"/> </coding> <text value="Volar"/> </locationQualifier> <description value="inner surface (volar) of the left forearm"/> <patient> <reference value="Patient/example"/> </patient> </BodyStructure>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.